Do not exceed 

the vehicle manufacturer’s specified safe load and carrying capacity.

 

CONNECTING TO 12 VOLT DC SUPPLY (12V Version): 

The Sprayer requires a 12 volt DC  power source.  A 3 metre loom is provided with the sprayer to 
allow the sprayer to be connected to the 12 volt DC source available.  The red wire is positive and 
the black is negative. If you extend the wire use wire of the same gauge or larger.  

An on/off switch is fitted to the sprayer control box to allow the sprayer to be switched off from the 
12 volt DC source to prevent accidental drain of power.  The switch also allows the pump to be shut 
down when the tank is empty preventing overheating and damage to the pump.  

A 30-amp fuse is fitted to the control box to prevent any potential damage to the electrical system 
of the vehicle. Consult your vehicle instruction manual for correct electrical connection. 

 

         

 

 

FITTING INSTRUCTIONS: 

It  is  recommended  that  the  sprayer  be  securely  attached  to  any  ATV  or  other  vehicle.  Refer  to 

manufacturer’s instructions for appropriate load limits and fitting positions.

 

Note: 1 litre of water = 1 kg. 

Never  fill  spray  tank to  a capacity  beyond  the  specified overall weight  limits  set  by your vehicle 
manufacturer. When fitted these should be firmly secured to approved attachment points on the 
ATV or other vehicle. 

 
 
 
 
 
 

 

 

 

Installations 

FUSE 

Содержание LT30-34

Страница 1: ...PRAYERS 300L LT30 S8 LT30 34 VICTORIA HEAD OFFICE Telephone 61 03 9215 2700 Fax 61 03 9215 2701 www silvan com au NEW ZEALAND Hamilton New Zealand Telephone 64 07 8496 033 Fax 64 07 8496070 www silvan...

Страница 2: ...reserves the right to make changes at any time without notice YOUR SPRAYER DETAILS Record the details of your Lightfoot Sprayer here for future reference when discussing service with your Silvan deal...

Страница 3: ...ot cover Conditions resulting from misuse use of incompatible chemicals exceeding machine specifications including overloading impact damage negligence accidental damage or failure to perform recommen...

Страница 4: ...tors and associated personnel are familiar with the legal regulations and codes of practice that apply to the safe use storage and disposal of spray chemicals Warning Before carrying out maintenance w...

Страница 5: ...ressure switch to cut the power to the motor When using the 12 volt spray unit in spot spraying applications the pressure switch can act to function as an automatic on demand switch stopping the pump...

Страница 6: ...ower The switch also allows the pump to be shut down when the tank is empty preventing overheating and damage to the pump A 30 amp fuse is fitted to the control box to prevent any potential damage to...

Страница 7: ...l to the sprayer 2 Check the filter is clean and undamaged see Maintenance section 3 Fill the tank with clean water 4 Check all pipes hoses hose clamps and connections for leaks or damage 5 Switch the...

Страница 8: ...praying is completed drain unused chemicals from the tank Rinse the tank with clean water then operate the sprayer with clean water in the tank to clean out the pump hose and spray lance Do not leave...

Страница 9: ...re can be measured using a car tyre pressure gauge TABLE A Spraying Pressure Bar 2 5 5 10 10 20 20 50 Psi 29 73 73 145 145 290 290 725 Surge Air Pressure Bar 2 2 5 5 7 7 Psi 29 29 73 73 102 102 Start...

Страница 10: ...ol is recirculated to maintain agitation within the tank System pressure is regulated by turning the knob B and observing the reading on the pressure gauge Turning the knob clockwise increases the pre...

Страница 11: ...an external suction filter Unscrew the cap on the filter housing in order to remove the filter Clean the filter with clean water and a bristle brush do not use a wire brush or sharp object as this may...

Страница 12: ...e that the tyres are correctly inflated Measure and mark 100 metres Approach the starting mark at the required spraying speed and accurately measure the time in seconds to reach the finishing mark The...

Страница 13: ...ray Width Breakback Facility Part Number Compatibility LT30 S8 2 1 05 meters 2 meters NO L99 09 YES 3 2 05 meters 3 meters NO L99 08 YES 4 3 meters 4 meters NO RP1 10 YES Note Indicates a Pressure Reg...

Отзывы: