![Silicon Laboratories ZigBee Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/silicon-laboratories/zigbee/zigbee_user-manual_1271900016.webp)
Here is an example of the commands used to command the reference design to transmit a modulated carrier at channel 15 with a pow-
er of 13 dBm until the next device power cycle.
Note:
It is assumed the gateway already created a network and that the reference design has joined this network with device ID 0x1234:
zcl mfg-code 0x1002
zcl mfglib-stream 15 13 0
send 0x1234 1 1
UG171: ZigBee
®
Smart Outlet Reference Design (RD-0051-0201) Kit User's Guide
Firmware
silabs.com
| Smart. Connected. Energy-friendly.
Rev. 0.1 | 15