4.1.21.3 I2C Fast-mode Plus (Fm+)
Table 4.40. I2C Fast-mode Plus (Fm+)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
f
SCL
0
—
1000
kHz
SCL clock low time
t
LOW
0.5
—
—
µs
SCL clock high time
t
HIGH
0.26
—
—
µs
SDA set-up time
t
SU_DAT
50
—
—
ns
SDA hold time
t
HD_DAT
100
—
—
ns
Repeated START condition
set-up time
t
SU_STA
0.26
—
—
µs
(Repeated) START condition
hold time
t
HD_STA
0.26
—
—
µs
STOP condition set-up time
t
SU_STO
0.26
—
—
µs
Bus free time between a
STOP and START condition
t
BUF
0.5
—
—
µs
Note:
1. For CLHR set to 0 or 1 in the I2Cn_CTRL register.
2. For the minimum HFPERCLK frequency required in Fast-mode Plus, refer to the I2C chapter in the reference manual.
MGM13S Mighty Gecko SiP Module Data Sheet
Electrical Specifications
silabs.com
| Building a more connected world.
Rev. 1.0 | 65