4.1.16 Current Digital to Analog Converter (IDAC)
Table 4.33. Current Digital to Analog Converter (IDAC)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
Number of ranges
N
IDAC_RANGES
—
4
—
ranges
Output current
I
IDAC_OUT
RANGSEL
0.05
—
1.6
µA
RANGSEL
1.6
—
4.7
µA
RANGSEL
0.5
—
16
µA
RANGSEL
2
—
64
µA
Linear steps within each
range
N
IDAC_STEPS
—
32
—
steps
Step size
SS
IDAC
RANGSEL
—
50
—
nA
RANGSEL
—
100
—
nA
RANGSEL
—
500
—
nA
RANGSEL
—
2
—
µA
Total accuracy, STEPSEL
0x10
ACC
IDAC
EM0 or EM1, AVDD=3.3 V, T = 25
°C
-3
—
3
%
EM0 or EM1, Across operating
temperature range
-18
—
22
%
EM2 or EM3, Source mode,
RANGSEL
AVDD=3.3 V, T = 25 °C
—
-2
—
%
EM2 or EM3, Source mode,
RANGSEL
AVDD=3.3 V, T = 25 °C
—
-1.7
—
%
EM2 or EM3, Source mode,
RANGSEL
AVDD=3.3 V, T = 25 °C
—
-0.8
—
%
EM2 or EM3, Source mode,
RANGSEL
AVDD=3.3 V, T = 25 °C
—
-0.5
—
%
EM2 or EM3, Sink mode, RANG-
SEL
= 25 °C
—
-0.7
—
%
EM2 or EM3, Sink mode, RANG-
SEL
= 25 °C
—
-0.6
—
%
EM2 or EM3, Sink mode, RANG-
SEL
= 25 °C
—
-0.5
—
%
EM2 or EM3, Sink mode, RANG-
SEL
= 25 °C
—
-0.5
—
%
Start up time
t
IDAC_SU
Output within 1% of steady state
value
—
5
—
µs
MGM13S Mighty Gecko SiP Module Data Sheet
Electrical Specifications
silabs.com
| Building a more connected world.
Rev. 1.0 | 55