Function Name:
BIT
gHmi_PbIsPushed
(U8 *boPbPushTrack, U16 *woPbPushTime)
Description:
This function is used to check if any of the push-buttons are pushed.
Output Parameters(s):
*boPbPushTrack : Read value of pushed button.
*woPbPushTime : Push time of pushed button.
Return Value:
Pushed state of push-buttons
Function Name:
BIT
gHmi_IsPbUnHandled
(void)
Description:
This function is used to check if there is unhandled push-buttons event.
Return Value:
True if there is unhandled push-button event.
Function Name:
U8
bHmi_PbGetLastButton
(U16 *woPbPushTime)
Description:
This function is used to read last pushed button(s), push track holder is erased if
button(s) was already released.
Output parameters(s):
*woPbPushTime : Push time of pushed button.
Return Value:
Push track holder of last pushed button(s)
Function Name:
void
vHmi_PbHandler
(void)
Description:
This function is used to handle push-button management.
Return Value:
None
Function Name:
void
vHmi_ShowPbOnLeds
(void)
Description:
This function is used to show the actual state of the push-buttons on the Leds.
Return Value:
None
Function Name:
BIT
gHmi_SwStateHandler
(void)
Description:
This function is used to handle switch state change.
Return Value:
True if state of switches has changed
Function Name:
U8
bHmi_GetSwState
(void)
Description:
This function is used to handle give the state
Return Value:
State
Function Name:
void
vHmi_InitBuzzer
(void)
Description:
This function is used to initialize the buzzer operation.
Return Value:
None
Note:
It has to be called from the initialization section.
Function Name:
void
vHmi_ChangeBuzzState
(eHmi_BuzzStates qiBuzzState)
Description:
This function is used to change the state the buzzer.
Input Parameter(s):
qiBuzzState : New state of the buzzer
Return Value:
None
Содержание EZRADIOPRO Si4060
Страница 24: ...AN633 24 Rev 0 7 Figure 20 Supply Current versus Time Diagram from Shutdown to RX State...
Страница 67: ...AN633 Rev 0 7 67 Figure 48 Variable Length Packet Reception Flowchart...
Страница 69: ...AN633 Rev 0 7 69 Figure 50 Packet Matching Reception Flowchart...
Страница 73: ...AN633 Rev 0 7 73 Figure 54 Packet Reception with Automatic RX Hopping Flowchart...
Страница 75: ...AN633 Rev 0 7 75 Figure 56 Packet Reception with Manual Rx Hopping...
Страница 80: ...AN633 80 Rev 0 7 Figure 62 Long Packet Transmission Workflow...
Страница 81: ...AN633 Rev 0 7 81 Figure 63 Long Packet RX Flowchart...