26
007-6419-002
4: System Monitoring
Solid red
An overheat condition has occurred.
For an overheat condition, consider the following:
- Ensure that the ambient room temperature is not too warm.
- Check the routing of cables and make sure all fans are present and
operating.
- Ensure that the chassis cover and air shrouds are installed.
- Verify that the heatsinks are installed properly.
Solid blue
Local UID button depressed. Use this function to locate the server
in a rack.
Blinking blue
IPMI-activated UID. Use this function to identif
y the server from a remote location.
Table 4-2
Universal Information LED States