UNOCODE PRO
Operating manual - English
84
Copyright Silca 2017
8.12 B
RUSH
REPLACEMENT
1) Open the rear compartment (ch.8.8, page 80).
2) Unscrew the two brush caps (M4) (fig. 64), remove and fit two new brushes.
3) Replace the two caps (M4).
4) Close the rear compartment.
5) Carry out Test 7 to check proper operation (ch.6.10, page 53).
Fig. 64
8.13 B
ATTERY
REPLACEMENT
Replacing the battery is a simple operation but must be carried out with care.
1) Disconnect the power lead from the key-cutting machine.
2) Gain access to the bottom compartment.
3) Use pliers with insulated tips to grip the battery and pull it out, taking care to push towards the pressure tab to
remove from its shaped housing.
4) Use the pliers with insulated tips to introduce the new battery, inclining it and pushing against the tab to help it enter
the shaped housing.
5) Close up the machine and connect to the mains.
6) Reconfigure the date and time on the machine (Ch.6.11, page 61).
ATTENTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
ATTENTION: for UTP machine version see the Date/Time synchronisation procedure (Ch.6.8.2)
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS (Ch.9 "DISPOSAL", page 86).
Fig. 65
M4
insulated points
with adhesive tape