User’s Manual MH3111 

page 8 of 8 

If device should be certificated for its accuracy, it is the best solution to return it with the referring sensors to 
the manufacturer. 
Only the manufacturer is capable to do efficient recalibration if necessary to get results of highest accuracy! 

8 Specification 

Measuring ranges: 

Display range: 

max. -19999...19999 digit, depending on connected sensor 

Resolution: 

depending on connected sensor 

Pressure units: 

mbar, bar, kPa, MPa, mmHg, PSI, mH

2

selectable depending on connected sensor  

Accuracy: (typ.) 

±0,1%FS  

(at nominal temperature)

 

Measuring rate: 

4 meas./sec  

Nominal temperature: 

25°C 

Sensor: 

All sensors of the MSD and MXD..-series without recalibration can be connected 

Connection:  

Mini-DIN-Socket with locking mechanism  
The sensor will automatically be detected, the measurement range settings are set 
referring to sensor data 

Additional Functions: 

Power-Off-Function:  

Device will be automatically switched off if no key is pressed/no interface 
communication takes place for the time of the power-off delay. The power-off delay 
can be set to values between 1 and 120 min.; it can be completely deactivated.  

Display

2 four digit LCDs (12.4mm high and 7 mm high) for measuring values, and for min/ 
max memories, hold function, etc. as well as additional functional arrows. 

Pushbuttons

:  

6 membrane keys 

Interface

Serial interface (3.5mm jack) can be connected to RS232 or USB interface of a PC 
via electrically isolated interface adapter GRS3100, GRS3105 or USB3100 (see 
accessories). 

Power supply

:  

9V battery, type: IEC 6F22  (included in scope of supply)  
as well as additional d.c. connector (diameter of internal pin 1.9 mm) for external 
10.5-12V direct voltage supply. (suitable power supply: GNG10/3000) 

Power consumption:  

< 1.6 mA 

Low battery warning: 

' bAt ' 

Housing

:  

impact-resistant ABS, membrane keyboard, transparent panel, Front side IP65 

Dimensions:  

142 x 71 x 26 mm (L x W x D) 

Wight:  

approx. 150 g 

Working temperature: 

-25...+50°C

Allowable rel. humidity:  0...95 %RH (not condensing) 
Storage temperature: 

-25...+70°C

EMC

The device corresponds to the essential protection ratings established in the 
Regulations of the Council for the Approximation of Legislation for the member 
countries regarding electromagnetic compatibility (2004/108/EG).  
Additional fault:   <1%  

9 Disposal notes 

This device must not be disposed as ‘residual waste’. To dispose this device, please send it directly to us 
(adequately stamped). We will dispose it appropriately and environmentally friendly. 

SIKA Dr.Siebert & Kühn GmbH & Co. KG ·• Struthweg 7–9 • 34260 Kaufungen • Germany • 

 +49 5605 803-0 • 

 +49 5605 803-54 • 

 [email protected] • www.SIKA.net 

Содержание MH3111

Страница 1: ...r s Manual Handheld Pressure Meter MH3111 as of Version 6 4 for MSD or MXD Pressure Sensors SIKA Dr Siebert K hn GmbH Co KG Struthweg 7 9 34260 Kaufungen Germany 49 5605 803 0 49 5605 803 54 info sika...

Страница 2: ...URE SENSORS 5 2 3 P OFF AUTO POWER OFF TIME 5 2 4 ADR BASE ADDRESS OF INTERFACE 5 2 5 OFFS ADJUSTUNG SENSOR ZERO DISPLACEMENT 5 2 6 SCAL ADJUSTUNG SENSOR SCALE 5 3 MEASURING OF WATER LEVEL DISPLAY UNI...

Страница 3: ...e product as safety or emergency stop device or in any other application where failure of the product could result in personal injury or material damage Failure to comply with these instructions could...

Страница 4: ...max key 2 shows the maximum of the measured value Pressing it again hides them To clear the max memory press key max for 2 seconds Min Memory Pressing min key 5 shows the minimum of the measured valu...

Страница 5: ...s the absolute pressure at sea level zero 2 3 P oFF Auto Power Off Time The device will be automatically switched off if no key is pressed no interface communication takes place for the time of the po...

Страница 6: ...ASYCONTROL Universal multi channel software EASYBUS RS485 or MH3000 operation possible for real time recording and presentation of measuring data of one MH3xxx device in the ACCESS data base format In...

Страница 7: ...System Messages Display Meaning What to do Low battery power device will only continue operation for a short period of time Replace battery Battery empty Replace battery Mains operation without batter...

Страница 8: ...for measuring values and for min max memories hold function etc as well as additional functional arrows Pushbuttons 6 membrane keys Interface Serial interface 3 5mm jack can be connected to RS232 or...

Отзывы: