Operation
Technical changes reserved
- 29 -
Service password:
The service password is not required for pa-
rameter settings which are relevant for op-
eration.
The service password is reserved for service
technicians and not provided to customers.
7.1.3
Totalizer
The TOTALIZER functional class includes the
following functions:
For changing the current settings and pa-
rameters the customer password is needed.
Otherwise, the settings only can be watched
but not be changed.
The ESC key is used for discarding changes.
Totalizer unit:
For selecting the desired function please use
the key
or
.
After choosing the function
Totalizer
unit
and pressing ENTER key, the current
forward and reverse totalizer unit will be
displayed.
Example:
How to change the parameter please refer to
Section "Selection window / make a selec-
tion".
The following units are available:
Volume units
m3
Cubic meter
l
Liter
USG Gallon (US)
UKG Gallon (brit.)
ft3
Cubic feet
Mass units*
kg
Kilogram
t
Tonne
*
When selecting a mass unit
the liquid density is
certainly required (
The changes will be confirmed by pressing
the ENTER key and the new unit will be ac-
tive as well for the forward totalizers and the
reverse totalizers.
Notice
When the unit is changed, the totali
z-
ers will be reset to 0.00 automatically!
Totalizer reset:
The display electronics of the VMM has three
independent totalizers.
Totalizer 1 and Totalizer 2 for the forward
flow and a totalizer for reverse flow.
Totalizer unit
[ USG ]