INSTALLATION INSTRUCTIONS
PowerForm Area & Flood
PN:443560815050
Rev: C
SlipFitter (SF)
Page 2 of 6
Signify Canada Ltd./Signify Canada Ltée.
281 Hillmount Road,
Markham, ON, Canada L6C 2S3
Signify North America Corporation
200 Franklin Square Drive
Somerset N.J. 08873, USA
© 2018 Signify Holding. All rights reserved. This document contains information relating to the product portfolio
of Signify which information may be subject to change. No representation or warranty as to the accuracy or
completeness of the information included herein is given and any liability for any action in reliance thereon is
disclaimed. The information presented in this document is not intended as any commercial offer and does not
form part of any quotation or contract. All trademarks are owned by Signify Holding or their respective owners.
www.gardcolighting.com
STEP 1:
To access wire splice area, remove (2) #8
-
32 Splice cover screws, splice
cover, and gasket.
STEP 2:
Route the supply wires through the Tenon. Secure the supply wire to keep
from sliding back down the Tenon. Route the wires through SlipFitter Arm into
splice area.
STEP 3:
Holding routed wires in splice area, carefully lower luminaire onto Tenon.
Check to insure that wires are not pinched between inside of SlipFitter Arm
and top of Tenon and that luminaire and wires rotate freely.
SF
-
SlipFitter Arm Mounted on
VERTICAL
Tenon DOES NOT require the 3/8
-
16 x
3
-
1/2”
bolt
thru the SlipFitter Arm and Tenon.
Note: Tenon must be 4.00" or longer.
(4) 1/2
-
13”
Allen
Socket Head bolts
(2) #8
-
32 Splice
Vertical
SlipFitter Arm mounts
to a
2” (2
-
3/8”
O.D.)
CAUTION:
Philips Lighting assumes no responsibility for the struc-
tural integrity of the Tenon. The EPA value of the luminaire
CANNOT exceed the maximum loading Value of the Ten-
on. These calculations must be checked.
Splice Area
SlipFitter Arm