INSTALLATION INSTRUCTIONS
PowerForm Area & Flood
PN:443560815050
Rev: C
SlipFitter (SF)
Page 3 of 6
Signify Canada Ltd./Signify Canada Ltée.
281 Hillmount Road,
Markham, ON, Canada L6C 2S3
Signify North America Corporation
200 Franklin Square Drive
Somerset N.J. 08873, USA
© 2018 Signify Holding. All rights reserved. This document contains information relating to the product portfolio
of Signify which information may be subject to change. No representation or warranty as to the accuracy or
completeness of the information included herein is given and any liability for any action in reliance thereon is
disclaimed. The information presented in this document is not intended as any commercial offer and does not
form part of any quotation or contract. All trademarks are owned by Signify Holding or their respective owners.
www.gardcolighting.com
SF
-
Slip Fitter Arm Mounted on VERTICAL Tenon
(Cont
’
d)
Note: Tenon must be 4.00" or longer.
STEP 4:
Using 3/8" Allen wrench, hand tighten (4) Allen Socket Head bolts, until tip of
screws engage Tenon. (Do not fully tighten).
•
Rotate to correct horizontal aiming position. Tighten the bolts to ap-
prox. 43 ft
-
lbs.
STEP 5:
Make wire connections per NEC or applicable local codes. When complete,
replace splice cover, gasket, and (2) screws removed in Step 1. Insure that
gasket is correctly in place before tightening splice cover and screws.
AIMING INSTRUCTIONS
Vertical Mount Tenon
STEP 1:
To adjust the angle, loosen the (1)
1/2
–
13
x
2”
hex
bolt located in SlipFitter Arm. (Do not remove
bolt.) Loosen only enough to allow rotation on
cast teeth.
STEP 2:
The angle of the luminaire can be adjusted up or
down in 4° increments.
STEP 3:
Using the degree indicators, shown as a guide,
rotate the luminaire to the desired position and
retighten the bolt in Step 1 to approx. 75 ft.
-
lbs.
STEP 4:
Energize luminaire to test installation.
(4)
1/2
-
13”
Allen
Socket Head bolts
1/2
-
13”
Hex Head
Tenon