Features

 

The P2.200 LS amplifier contains two identical

 

independent amplifier modules. Each has one Main and one 

Aux. input. Routing logic allows the Main and Aux. to mix; this allows the monitoring tone to pass at all times 
and the monitoring system to operate. If the PTT is operated, the Main input overrides the Aux. 

Each  module’s  status  is  displayed  on  the  front  panel  along  with  an  output  level  bar  graph  and  status 
indicators. All sections of the amplifier and charger are constantly monitored for faults or abnormal operation: 

The  load  monitoring  checks  the power absorbed by the loudspeaker load at 22 kHz and compares this 
with the threshold and window levels set at installation. If the power drawn deviates outside the window a 
fault is indicated on the front and rear of the unit and signalled to other equipment via the relevant fault 
outputs. 

If the impedance monitoring tone is not being received by the amplifier, both the Load Hi and Load Low 
front LEDs light and the rear Tone Fail light shows. 

3

 

Should either leg of the loudspeaker wiring short to system earth this will also light the Load Hi and Load 
Low LEDs on the front panel, along with the Earth Fault LED on the rear. 

4

 

Mains power status is also monitored, along with the internal fuses, to give a complete picture of the state 
of the amplifier. 

The  load  monitoring  system  also  provides  an  output  to  drive  a  ‘hot  swap’  automatic  amplifier  replacement 
system,  via  the  HSP  port,  on  failure  of  the  amplifier  only.  Should  a  load  fail  short  or  open  circuit  but  the 
amplifier  is  still  OK,  the  hot  swap  output  will  not  operate.  This  means  that  any  loudspeakers  that  can  be 
driven will operate and leaves the hot swap amplifier available for use on another potential failure. 

The  output  from  each  module  is  presented  on  a  three-way  socket and is fully floating. The standard output 
voltages are 50V and 100V, allowing two modules to be connected in series to give 400W at 100V line. 

The power supply has a 24 Vd.c. battery input and an onboard battery charger. 

Technical Description

 

Amplifier Modules 

The  Aux.  and  Main  line  level  inputs  are  de-balanced  and  pass  via  level  controllers  and an analogue switch 
into a summing amplifier where they are mixed. If the contact input is asserted (470 ohms to ground) a logic 
circuit disconnects the aux. input. 

The protect circuit disconnects the output transformer when the voltage rails fall below 22 Volts, exceed 36 
Volts, or when a d.c. offset is present on the output rails. The signal then passes through to the output stage, 
which is a feed-forward current-mode bridge circuit and the output level meter monitors the level at this stage. 

The output current is passed through the primary of the output transformer and through a low value output-
sensing  resistor.  The  output  of  the  transformer  is  tapped  at  50  and  100  Volts.  If  the  50  Volt  taps  are 
connected in series the unit provides a single 400 Watt output at 100 V line. 

Power Supply 

A  large  capacitor  reservoir  provides  a  very  smooth  output,  even  under  large  current  surges.  Two  separate 
internal 10 Amp fused outputs connect to the two amplifier modules.  

A  separate  low-current  feed  passes  via  the  sleep  enable  selector  link  into  the  sleep  timer  section.  Another 
feed passes, via the Aux. on LED (this shows that the Aux. power is available on the rear connector) through 
a  3  Amp  fuse  to  the  Aux.  power  connector.  With  mains  voltage  operation  this  unregulated  output  is  at 
approximately 32 Vd.c. When mains has failed, this output is connected to the battery and therefore operates 
at battery voltage level. 

A 27.6 Volt regulator is also taken off this line and used to charge external batteries via a 20 Amp fuse. 

PSU and amplifier faults are returned into the monitoring circuit from both amplifiers, slugged to prevent false 
faults being reported externally, and passed to the open collector fault outputs on the SIP port. A fourth open 
collector output is normally set as OK (normally closed) and opens when any fault occurs. 

Operation Instruction Manual 

Pulse 2.200 LS

 

Dual 200W 100V line Amplifier with Monitoring

 

Содержание Pulse 2.200 LS

Страница 1: ...d in series to give 400W at 100V line The power supply has a 24 Vd c battery input and an onboard battery charger Technical Description Amplifier Modules The Aux and Main line level inputs are de balanced and pass via level controllers and an analogue switch into a summing amplifier where they are mixed If the contact input is asserted 470 ohms to ground a logic circuit disconnects the aux input T...

Страница 2: ... AUTOMOTIVE BLADE TYPE EXCEPT MAINS INLET FUSE AMP A FAULT AMP B FAULT OK SIP4 PSU FAULT SIP3 AMP B FAULT SIP2 AMP A FAULT SIP1 SLEEP LINE IN AUX 0dB LEVEL P2 200LS AMPLIFIER MODULE BLOCK DIAGRAM TWO PER P2 200LS ISSUE 1 LINE IN MAIN 0dB LEVEL MONITOR ANALOGUE SWITCH ANALOGUE SWITCH CONTROL 50 V 100V 0V CONTACT PTT IN OPEN CIRCUIT FAULT SHORT CIRCUIT FAULT DETECT FAULT HSP2 LOAD HIGH FAULT HSP1 LO...

Страница 3: ...sed as it does not comply with BS5839 8 5 Load Hi The load monitoring system has detected an open circuit or higher impedance than was set at commissioning 6 Load Low The load monitoring system has detected a closed circuit or lower impedance than was set at commissioning 7 Contact Fault The main input control contact or wiring is either open circuit or short circuit 8 Tone fail Load Hi and Load L...

Страница 4: ...6 Aux audio input 11 LEDs OC The main input control wiring is open circuit SC The main input control wiring is short circuit E Earth fault The 100V loudspeaker line has a short to ground Hi Load High Open circuit detected or a impedance higher than commissioned TF Tone Fail The monitor tone on the input signal is not detected Lo Load Low Closed circuit detected or lower impedance than commissioned...

Страница 5: ...dust levels 5 susceptible to vibration Caution To prevent electric shock do not remove the cover AC power operation Due to the size and inductance of the power transformer depending on where in the cycle the power is switched on the inrush current that is drawn when this device is connected can be as much as 150 Amps It is therefore essential that mains power is only derived from an automatic soft...

Страница 6: ...awn from each amplifier channel is 11 Amps 22 Amps total 10 of the peak value is therefore 2 2 Amps or for 30 minutes 1 1 AHr However batteries must be de rated by 50 at high discharge rates and so a figure of 2 2 AHr is taken If 60 minutes in alarm is required 4 4 AHr will be required Total Battery Capacity Add alarm state battery capacity to the quiescent capacity and the capacity required is 9 ...

Страница 7: ...oudspeaker line continuity be monitored not the loudspeakers themselves Loudspeaker Spurs Note that this implies that spurs are not allowed If a loudspeaker output is to be split to drive two circuits this is only possible using the SPLIT100 Line Splitter which protects either circuit against a short circuit in the other circuit The SPLIT100 is provided with one EOL device so that one EOL can be u...

Страница 8: ...a 22Khz monitoring tone This will be shown by a sticker on the unit iX LS units without a sticker must be replaced with 22Khz units Older iX LS units use a 20 Khz monitoring tone End of line units supplied with the amplifier must also be fitted Connecting the P2 200 to a SigNET SS2n Network station including battery backup 1 SS2n feeding both amplifier modules 2 SS2n feeding only one amplifier mod...

Страница 9: ...lead from a SigNET routing matrix is connected to both Main Inputs a 2 Check that the monitoring tone is not disabled the tone fail TF indicator is not lit 3 No audio should be routed into the Main input except for the 22 kHz monitoring tone 4 Using an oscilloscope e g Maplin Part No IN02158 or true r m s voltmeter RS218 0265 capable of reading up to 25 kHz connect to each 100V line output across ...

Страница 10: ...led default Battery monitoring enabled Disabled Battery monitoring disabled this removes the battery fault from the front panel if batteries are not fitted Sleep Mode Disabled default This facility is not used as it does not comply with BS5839 8 All other jumpers on the unit are all for SigNET s internal use test purposes only SIP port These four fault outputs pass via a 16 pin dual in line socket...

Страница 11: ...ting area 75mA 150mA with fault lights lit and full load monitoring 11A Physical Material Colour Width Height Depth Weight 18swg Zintec sheet steel Black RAL 9500 semi gloss 430mm 88mm 315mm behind front panel 17kg Power supply charger AC input DC input Charging voltage Charging current Monitoring Aux Supply SIP Port 230 VAC 20 22 to 34 V DC 27 6 V DC 3A Short circuit and battery high impedance 1A...

Страница 12: ...se locations Fuses are commonly available automotive blade types SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE SigNET AC Limited 6 Tower Road Glover Estate Washington Tyne Wear NE37 2SH Tel 44 0 191 417 4551 Fax 44 0 191 417 0634 info signet ac com www signet ac com ...