Digital I/O
Setting up the Events Outputs
The 1100R+
has six outputs that can drive an external device according to various “events” in the
tester. These events occur as the tester powers up, learns a cable, tests a cable, and displays
the test results. Controlling an output line requires two triggering events.
1. From main menu, press
Set Preferences.
2. Scroll down and press
Set Digital
Outputs.
3. Scroll up or down to the digital output pin
you want to setup.
4. Press
S
(set).
5. Scroll up or down to the test event you
want to start the operation of the output
device; press
Accept.
6. Press
R
(reset)
.
7. Scroll up or down to the event needed to
stop the operation of the output device and
press
Accept.
8. Press back to return from the
Digital
Output
selection menu.
The
S
event sets (or sinks) the
output pin to ground thereby
allowing current to flow through the
output circuit.
The
R
event resets the output pin to
the original no current flowing state.
Note:
Two of the outputs are factory enabled with default triggers. The pin 7 output is set with
“Good Light On” and reset with “Good Light Off”. Pin 8 is set with “Bad Light On” and reset with
“Bad Light Off.”