51
Cable Error
Messages
Cable Error Messages
The four types of cable error messages are:
Low Voltage, Component, High Voltage,
and
Intermittent.
When a tested cable has an error:
To see the detailed cable error message:
Press
View Errors,
and scroll down
to see the whole page,
OR
Press
Print Errors
if a printer is connected
.
The detailed error message shows the
Error
Signature,
and the specific error or errors
found (in this case, a short to Net 1).
Using Error Tones
When the tester finds a cable error, it makes error tones based on the type of error:
Opens = single beep
Shorts = double beeps
Miswires = triple beeps
Error tones give the operator instant feedback if there is a problem. For instructions on changing
speaker volume, see
Changing the Speaker Volume
on page 9 and
Changing Volume and
Display Controls
on page 69.
The red LED lights.
Error tones
sound based
on the type
of error.
The tester displays
the type of test error
on the screen.
ERROR: BBF085-2X8NH
NET 1: SHORT
J1-001 J3-001 TO
J1-002 J3-002
Cable Error
Messages