31
CTLWIN
Editing Test Programs
The following examples illustrate how to edit test programs using CTLWIN.
Example 1: Changing Default Cable Description and/or Point Labels
Original Test Program Edited Test Program
Example 2: Modifying Component Test Values and Links
Original Test Program Edited Test Program
*477BDD-MULTI
(477BDD-MULTI
J1 ACEFA1
J2 1A59C0
1 J1-001 J2-001
2 J1-004 J2-002
3 J2-007 J2-008
CHECK COMPONENTS
1 RESIS J1-002 J2-007 42.3 ohm 10 %
2 RESIS J1-008 J2-009 6.64 K ohm 10 %
3 CAP J1-006 J1-002 420 nF 10 %
4 LINK J1-005 J2-005
)
*477BDD-MULTI
(477BDD-MULTI
J1 ACEFA1
J2 1A59C0
1 J1-001 J2-001
2 J1-004 J2-002
3 J2-007 J2-008
CHECK COMPONENTS
1 RESIS J1-002 J2-007 42.2 ohm 5 %
2 RESIS J1-008 J2-009 6.65 K ohm 5 %
3 CAP J1-006 J1-002 420 nF 10 %
4 RESIS J1-005 J2-005 1M ohm 10%
)
*DT SONAR MODULE
(984123-2J8NM
J1 D507F1
CONNECTION RESIS 10.0 ohm
LV INSULATION RESIS 100 K ohm
INSULATION RESIS 5.00 M ohm
1 J1-001 J1-002
2 J1-003 J1-004
LABELS
J1-001 = HEADER_PIN1
J1-002 = HEADER_PIN2
J1-003 = RED_WIRE
J1-004 = BLUE_WIRE
)
*984123-2J8NM
(984123-2J8NM
J1 D507F1
CONNECTION RESIS 10.0 ohm
LV INSULATION RESIS 100 K ohm
INSULATION RESIS 5.00 M ohm
1 J1-001 J1-002
2 J1-003 J1-004
)
Default point
labels
assigned custom
point labels.
Cable description
changed from the
Cable Signature to
a custom description.
Link command
changed to a
resistor command.
Learned resistor
values and default
tolerances edited.