55
Cable Error
Messages
Component Errors
The tester displays a component error if it senses a problem with an electrical component
programmed into the cable test. The tester detects component errors during the Low Voltage
cable test.
Bad Resistor and Bad Capacitor
The tester displays these messages when it senses a component with a measured value outside
the tolerance for the component programmed in the cable test.
Possible causes are:
The wrong value component is installed in the cable.
The correct component is installed, but is out of tolerance.
The connection to the component has high resistance and therefore, has affected the
tester’s ability to correctly measure the component value.
Missing Resistor, Missing Capacitor, and Missing Diode
The tester displays these messages when it does not sense a component where it should be in
the cable
.
Possible causes are:
A connection to the component is open.
The component has not been installed, is missing, or has a resistance greater than
1 M
Ω.
Bad Diode
The tester displays this message when it senses a defective diode condition.
Possible causes are:
The diode’s forward or reverse bias voltage drop is out of tolerance.
The installed diode is outside the measurement capability of the tester.
Reversed Diode
The tester displays this message when it senses a diode’s orientation is reversed.
Possible cause:
The diode is reversed in the cable.
NOT Twisted
Two wires are not twisted that should be.
No twisted pairs
The tester did not detect twisted pairs in the tested cable.
Wires are paired incorrectly
A wire is twisted with the wrong wire.