Signamax 065-1063FSx series RS-232/422/485 to 100Base/FX Device Server / Media Converter
25
6.2
Command Line Interface
Once you logged in and select the option of Command Line Interface, a window with a
command prompt will appear. Type
?
or
help
and it will show you the command list.
Command List
Command Definitions
backup:
Use this command to save configuration settings
to a file.
exit:
Type exit or logout and press
ENTER
to quit the program.
help:
To access the help commands list.
logout:
To logout from the device server.
ping:
Type
ping
followed by a
space
, and then the
IP address
of the device to
send a test signal. If a response is received, then the device is connected. To
view a full list of
ping
options, type ping and press
ENTER.
reset:
Type
reset config
and press
ENTER
to load factory default settings, or type
reset system
and press
ENTER
to restart the system.
show:
Type
show
to display a variety of device server settings.
set:
To configure the management settings, type the commands below, followed
by the
ENTER
key.
NOTE
: Separate each port of the command line with a space.
set admin
- follow the prompts to change the user name and password
set eth0
- the command is for changing the factory IP address setting. The syntax is
set eth0 ip
(new IP address)
network mask (
new network mask)
gateway
(new gateway). Use this command to set new Ethernet settings.