Signamax 065-1063FSx series RS-232/422/485 to 100Base/FX Device Server / Media Converter
10
5
User Interface Startup
There are two separate methods for configuring this Device Server / Managed Media
Converter for use. In the first section of this chapter, the Command line Interface (CLI)
or Menu-driven interface via the
Console Port
to set the device IP and TCP
configuration to monitor/managed the attached serial device via Serial IP Redirector
software. The second section will describe
CLI or Menu-driven via Telnet
configuration.
First, make the connection below:
DIP Switch 1 set to the ‘ON’ position
5.1
Console Port Access
The Device Server / Managed Media Converter is accessible via a terminal emulator
attached to the RS-232 console port. Please follow the steps below.
1. Attach the serial cable to COM port of computer and serial port of the device server.
2. Select Hyper Terminal from (start menu
programs
Accessories
communication) a window will appear, assign the connection name. Then select
the correct available COM port (COM1 or COM2). After this enter the port settings
as described below:
Bits per second: 38400
Data bits: 8
Parity: None
Stop bits: 1
Flow Control: None
3. Once connection is established, you will see a log-in screen.
Device
Server
Female
Female
Computer
RS-232 Cable