SDM 081
S-DIAS SAFETY DIGITAL MIXED MODULE
Page 32
07.02.2022
QuitComError
A communication error is canceled by writing to this server. If the safety.dlm
is used, the dlm can also cancel other errors starting with version 6.
The canceling of errors is forwarded to the Safety CPU and canceled with all
other errors in the Safety CPU.
Caution!
Canceling can activate safety outputs and thereby lead to unexpected
responses from machine elements.
If this function is provided through the visualization, a corresponding warning
should be displayed.
The server shows the status of the cancellation:
2
Busy canceling error
1
Busy cancelling communication error
0
Ready
-1
Error creating Safety statement via dlm
-2
Deactivation of user input request failed.
-3
Selection of module via Safety number failed
-4
Error during connection set-up with module via dlm (the
SafetyDesigner cannot be online while canceling errors!)
-5
Error canceling in the module failed
-6
Remove the Safety statement via dlm failed
Safe_Input[1-6]
Status of safe digital inputs 1 to 6.
Safe_Output[1-2]
Status of safe digital outputs 1 to 2.
UnSafe_Output[1-2]
With this server, the respective Safe output can be toggled as long as the
property "Enable Signal Used" is set to true in the settings of the output in the
SafetyDesigner.
SafeIOError
Shows which Safe in and output are in error mode with a bit code.
Bit 0
input 1
Bit 1
input 2
Bit 2
input 3
Bit 3
input 4
Bit 4
input 5
Bit 5
input 6
Bit 6
output 1
Bit 7
output 2
9.2.3
Communication Interfaces
ALARM
Downlink
With this downlink the corresponding alarm class can be placed via the
hardware editor.
Содержание SDM 081
Страница 21: ...S DIAS SAFETY DIGITAL MIXED MODULE SDM 081 07 02 2022 Page 19...
Страница 23: ...S DIAS SAFETY DIGITAL MIXED MODULE SDM 081 07 02 2022 Page 21 4 Mechanical Dimensions...
Страница 27: ...S DIAS SAFETY DIGITAL MIXED MODULE SDM 081 07 02 2022 Page 25 6 Wiring 6 1 Wiring Example...
Страница 35: ...S DIAS SAFETY DIGITAL MIXED MODULE SDM 081 07 02 2022 Page 33 9 3 Example...