ETV 1591-H 

 

Control Panel 

 
 
 
 
 

 

 Date of creation: 02.04.2013 

 Version date: 24.03.2015 

 Article number: 13-230-1591-HE 

Содержание ETV 1591-H

Страница 1: ...ETV 1591 H Control Panel Date of creation 02 04 2013 Version date 24 03 2015 Article number 13 230 1591 HE...

Страница 2: ...may be reproduced edited using an electronic system duplicated or dis tributed in any form print photocopy microfilm or in any other process without the express permission We reserve the right to mak...

Страница 3: ...up the data before the panel is shut down an integrated UPS is used to buffer the 24 V power supply The available interfaces can be used to exchange process data or configure the build in terminal A...

Страница 4: ...ellaneous 7 2 Mechanical Dimensions 8 3 Chemical Resistance 9 3 1 ASA Plastic Housing 9 4 Connector Layout 10 4 1 Front Connector 10 4 2 Rear Connectors 11 4 3 Applicable Connectors 13 5 Uninterruptab...

Страница 5: ...cess 29 5 6 1 Time Specification 29 5 6 2 Measuring 30 5 7 Battery Lifespan and Charge Discharge Curve 31 5 7 1 Battery Lifespan 31 5 7 2 Self Discharge 32 5 7 3 Battery Charging Curve 33 5 7 4 Batter...

Страница 6: ...10 Mounting Instructions 49 11 Wiring Guidelines 50 11 1 Ground 50 11 2 Shielding 50 11 3 ESD Protection 51 11 4 USB Interface Connections 51 12 Recommended Shielding for VARAN 52 12 1 Wiring from th...

Страница 7: ...A high speed 480 Mbit s 2x Gbit Ethernet RJ45 1x VARAN Out RJ45 4x optically decoupled inputs 4x optically decoupled outputs Internal interface connections and devices 1x TFT LCD color display 1x touc...

Страница 8: ...d current of a 4 A at voltages from 0 20 Vrms 0 28 3 Vp or b 100 VA Vp at voltages from 20 30 Vrms 28 3 42 4 Vp 1 3 Terminal Dimensions with battery Dimensions without battery 358 x 313 x 109 mm W x H...

Страница 9: ...cklighting LED Contrast typically 700 1 Brightness typically 400 cd m Angle CR 10 from left and right 80 above and below 70 1 6 Control Unit Touch panel analog resistive film glass touch panel Resolut...

Страница 10: ...ETV 1591 H CONTROL PANEL Page 8 24 03 2015 2 Mechanical Dimensions...

Страница 11: ...acid 5 None Ammonia hydroxide solution 10 at 23 C None Caustic soda 1 at 23 C None Caustic soda 35 at 23 C None Ethanol at 23 C None Isopropyl Alcohol at 23 C None Methanol at 23 C None Iso Octane at...

Страница 12: ...r a maximum total current of 500 mA It should be noted that many of the USB devices on the market do not comply with USB specifications this can lead to device malfunctions It is also possible that th...

Страница 13: ...pply X3 X4 digital in outputs X1 power plug Pin Function 1 24 V DC DIG IOs 2 24 V DC 3 GND 4 GND X2 battery Pin Function 1 NTC 1 2 Batt 3 Batt 4 NTC 2 X4 Output Pin Function 1 output 1 2 output 2 3 ou...

Страница 14: ...t load could cause a real time runtime error or runtime error By configuring the packet filter Firewall or Router accordingly however it is possible to connect a network with SIGMATEK hardware to a th...

Страница 15: ...r function correctly Therefore it is recommended that every USB stick be tested before actual use 4 3 Applicable Connectors USB 4 pin type A downstream connector Ethernet 8 pin RJ45 VARAN 8 pin RJ45 P...

Страница 16: ...ent supply battery and electronics 5 1 Simplified Block Diagram The battery is charged with the connected 24 V main supply The UPS is active when a failure of the external 24 V main supply is detected...

Страница 17: ...nd temperature ranges are discussed in the following chapters 5 2 1 Electrical Requirements for the Battery Pack Battery type maintenance free nickel metal hybrid NiMh battery pack Voltage typically 1...

Страница 18: ...g 5 2 3 Environmental Conditions Battery storage tempera ture 20 60 C Battery operating tem perature 0 50 C 3 3 Temperatures above and below this range are not allowed for the battery used as it can b...

Страница 19: ...tage measured under load the low charge condition can be determined Contrary thereto the charging or open circuit voltage cannot be evaluated The voltage under load is used for example to immediately...

Страница 20: ...232 the UPS configu ration shutting down Windows and sending data to the application The SigmatekUpsMonitor Windows service must be used for the complete functional scope of the UPS 5 5 Using the Inte...

Страница 21: ...to shutdown EGetShutdownTimerActive 0x05 Info as to whether the shutdown timer is active EGetTimeTillShutdown 0x06 Current shutdown timer value EGetComPort 0x07 Name of the COM port used for the UPS E...

Страница 22: ...EGetBatteryExchangeNeeded Description Request ID Instruction Sequence Retrieve information as to whether the battery is OK or must be exchanged The battery is evaluated by the Windows service Sigmatek...

Страница 23: ...ual battery voltage Conversion factor 100 d 1 V Value range 10 15 V 25 09 V Accuracy 0 06 V Byte sequence Little Endian Updating every second 12 13 WORD Measurement value Battery volt age under test l...

Страница 24: ...e buffered supply is powered vis the 24 V main supply while the battery is connected D1 Status 1 The UPS is active the buffered supply is provided from the battery D2 D3 Status warning 1 The battery i...

Страница 25: ...ttings from UPS active to the shutting down of Windows 0x04 Open connection Send 4 byte Request ID 0x04 to Pipe Read 4 byte answer Close connection Answer ByteNo Data type Info 1 4 DWORD Shutdown time...

Страница 26: ...4 DWORD Time remaining until Windows shutdown in seconds EGetComPort Description Request ID Instruction Sequence Read the selected serial interface 0x07 Open connection Send 4 byte Request ID 0x07 to...

Страница 27: ...n Answer ByteNo Data type Info 1 BOOL FALSE automatic shutdown of windows disabled TRUE automatic shutdown of windows enabled EGetCableType Description Request ID Instruction Sequence Read the battery...

Страница 28: ...shutdown Default Enabled ESetCableType 0x83 Sets the battery extension cable type used Default Type 0 battery connected directly EResetBatteryExchangeNeeded 0xC0 Resets the Battery exchange needed war...

Страница 29: ...yteNo Data type Info 1 BOOL FALSE Error TRUE the serial interface was set in the configuration EEnableAutoShutdown Description Request ID Instruction Sequence Enable disable the automatic shutdown of...

Страница 30: ...ot used 0x04 Type4 not used Read 1 byte boolean answer Close connection Answer ByteNo Data type Info 1 BOOL FALSE Error TRUE The cable type was enabled disabled in the configuration EResetBatteryExcha...

Страница 31: ...the first 24 hour charging cycle the sys tem switches to a pulsed charging cycle and every 24 h an 8 h continuous charg ing cycle is performed to maintain the voltage see image 1 2 The charging circu...

Страница 32: ...24 h charging ended 4 24 h charging stop 5 Start of 8 h charging after 24 hour charging stop pulsed charging Orange curve battery voltage While the battery is charging 2 The curve corresponds to the...

Страница 33: ...ess used a battery lifespan of at least 6 years can be ensured The battery type used has over chargeable cells The UPS system implemented limits the voltage and current thereby providing double protec...

Страница 34: ...ffected Operating with a discharged battery also does not destroy it however there is also no buffer time available for the target hardware battery deep discharge protection Self discharge curve of a...

Страница 35: ...ss Orange curve battery voltage After a charging time of approximately 18 hours the battery reaches the maximum possible charge can be seen on the orange flat voltage drop after 18 hours Because to th...

Страница 36: ...point the 24 h charging stop begins see cycles 5 7 4 Battery Discharging Process The discharge curve of a fully loaded battery is measured up to the deep discharge thresh old The test device is the E...

Страница 37: ...be included in the calculation of the battery voltage measurement The UPS calculates the voltage drop The UPS is configured via the Windows service SigmatekUpsMonitor For the configura tion of the ca...

Страница 38: ...ambient conditions this case should not occur In addition the following condition must always be met The USV must be active due to a main power loss this means that the device must be powered by the b...

Страница 39: ...ousing The 4 mounting screws on the battery housing must be removed Note the 4 clearance bolts between the battery pack and the housing must be secured with the screws when mounting the battery pack T...

Страница 40: ...IA the outputs on the primary 5 V and the secondary 24 V sides are isolat ed using optic couplers according to application class 3 pollution degree 2 For the inputs the primary 24 V and the secondary...

Страница 41: ...ainst 0 V An excessively long or too thin 0 V conductor can lead to undesired responses from the outputs of the affected module The outputs can be turned off by disconnecting the 24 V supply voltage A...

Страница 42: ...ETV 1591 H CONTROL PANEL Page 40 24 03 2015 6 2 Disconnecting Inductive Loads...

Страница 43: ...24V 4 Braking of in ductive loads is limited to 12 7 V as shown in the graph below However an additional protection circuit directly on inductive loads is recommended freewheeling diode to avoid a sys...

Страница 44: ...ended to ensure error free function The following guide lines should be observed Avoid parallel wiring between input lines and load bearing circuits Protective circuits for all relays RC networks or f...

Страница 45: ...function The following guidelines should be observed Avoid parallel connections between input lines and load bearing circuits Protective circuits for all relays RC networks or free wheeling diodes Co...

Страница 46: ...1 H CONTROL PANEL Page 44 24 03 2015 Input 1 24 V collection bus 24 V collection bus Input 1 Ground bus GND 6 5 1 2 wire Initiators and Mechanical End Switches Schematic 2 6 5 2 3 wire Initiators Sche...

Страница 47: ...ugh capacity to preserve data in the absence of a supply voltage for up to 4 years Battery order number 01 690 067 MANUFACTURER DATA Lithium battery VARTA 3 0 V 1 0 Ah WARNING Battery may explode if m...

Страница 48: ...ETV 1591 H CONTROL PANEL Page 46 24 03 2015 8 Exchanging the Battery Hard Drive Disconnect the power to the ETV Open the locking screws on the back of the terminal with a PH 1 screwdriver...

Страница 49: ...CONTROL PANEL ETV 1591 H 24 03 2015 Page 47 Open the locking screws of the bat tery lock with a PH 1 screwdriver Carefully remove battery...

Страница 50: ...TROL PANEL Page 48 24 03 2015 Loosen the cable binders and discon nect battery plug Next connected the new battery secure it with cable binders and place it in the provided holder Finally re place the...

Страница 51: ...Watts To ensure the necessary air circulation for cooling the following mounting instructions must be followed 10 Mounting Instructions The following distance from the housing should be maintained Rea...

Страница 52: ...ate a low ohm ground connection only then can error free operation be guaranteed The earth connection should have a maximum cross section and the larges electrical surface possible 11 2 Shielding For...

Страница 53: ...minal the potential should be equalized by touching the control cabinet or earth terminal This will allow the dissipa tion of electrostatic loads caused by clothing shoes 11 4 USB Interface Connection...

Страница 54: ...operated outside the control cabinet the correct shield ing is required This is especially important if due to physical requirements the bus cables must be placed next to sources of strong electromagn...

Страница 55: ...ARAN component If the Ethernet lines are connected from a VARAN component to a VARAN node located outside the control cabinet the shielding should be placed at the entry point to the control cabinet h...

Страница 56: ...upport is required A requirement therefore is that only IP67 modules and connect ors can be used outside the control cabinet These components are very robust and noise resistant The shielding for all...

Страница 57: ...etc can induce interference in a VARAN bus line Spike voltages are dissipated over the metallic housing of a RJ45 connector Noise is conducted through the control cabi net housing without further acti...

Страница 58: ...cting Noise Generating Components With the connection of power components that generate strong electromagnetic interfer ence it is also critical to ensure correct shielding The shielding should be pla...

Страница 59: ...etween Two Control Cabinets If two control cabinets must be connected over a VARAN bus it is recommended that the shielding be located at the entry points of both cabinets Noise can be thereby prevent...

Страница 60: ...the cloth and not directly on the terminal The cleaning solution should not be allowed to reach the terminal electron ics for example through the ventilation slots No erosive cleaning solutions chemi...

Страница 61: ...ttery Exchange 6 Digital In and Outputs 5 A changed to 4 A Changed from circa to max 1 minute Block diagram changed Internal energy storage constant current changed Supply voltage and current consumpt...

Страница 62: ...ETV 1591 H CONTROL PANEL Page 60 24 03 2015...