Critical states can occur:
With a new, uncharged battery
If the battery was not charged long enough
If too many consecutive discharges were performed successively
If the charging circuit is not functioning correctly
If the battery is defective
5.4
UPS Interface
The Windows service "SigmatekUpsMonitor
“functions as the UPS interface. Sig-
matekUpsMonitor manages the communication with the UPS via RS232, the UPS configu-
ration, shutting down Windows and sending data to the application.
The SigmatekUpsMonitor Windows service must be used for the complete functional scope
of the UPS.
5.5
Using the Interface for the UPS
The Windows service and UPS are configured via a Named-Pipe server. The application
can configure the UPS and read data for the visualization with the following Pipe functions.
The connection to the Named-Pipe server is established through the name of the Pipe
server and the individual GUID (Globally Unique Identifier).
The name of the Pipe server with the following GUID:
UpsStateServer{A7AF64DE-35C1-4f90-B8B0-8AC24A92F39C}