CONTROL PANEL
ETV 1591-H
24.03.2015
Page 23
A battery is considered NOT connected when the status bits
UPS info D0 (UPS standby) = 0
UPS info D1 (UPS active) = 0
UPS info D5 (battery almost empty or not connected) = 1
Any other combination of status bits means: The battery is connected.
EGetShutdownTime
Description
Request-ID
Instruction Sequence
Read the current time settings from
UPS active to the shutting down of
Windows.
0x04
Open connection
Send 4-byte Request-ID (0x04) to Pipe
Read 4-byte answer
Close connection
Answer
ByteNo.
Data type
Info
1-4
DWORD
Shutdown time setting in seconds
EGetShutdownTimerActive
Description
Request-ID
Instruction Sequence
Read whether the shutdown time is
active (UPS is active and the
shutdown timer is counting)
0x05
Open connection
Send 4-byte Request-ID (0x05) to Pipe
Read 1-byte (boolean) answer
Close connection
Answer
ByteNo.
Data type
Info
1
BOOL
FALSE = Timer is inactive
TRUE timer is active