CONTROL PANEL
ETV 1591-H
24.03.2015
Page 27
ESetComPort
Description
Request-ID
Instruction Sequence
Sets the serial interface for the UPS.
0x81
Open connection
Send 4-byte Request-ID (0x81) to Pipe
Write 4-byte long X of the following string
Write X-
byte string (ASCII) (e.g. „\\.\COM1“)
Read 1-byte (boolean) answer
Close connection
Answer
ByteNo.
Data
type
Info
1
BOOL
FALSE = Error
TRUE = the serial interface was set in the configuration
EEnableAutoShutdown
Description
Request-ID
Instruction Sequence
Enable/disable the automatic shutdown
of Windows by the SigmatekUpsMoni-
tor Windows service
0x82
Open connection
Send 4-byte Request-ID (0x82) to Pipe
Send 1-byte (Boolean) to Pipe
TRUE = enabled, FALSE = disabled
Read 1-byte (boolean) answer
Close connection
Answer
ByteNo.
Data
type
Info
1
BOOL
FALSE = Error
TRUE = The automatic shutdown was enabled/disabled in the configuration