background image

13

4. Maintenance

The utilisation level of the power source and its working environment should be taken into 
consideration in planning the frequency of maintenance of the machine. Appropriate use and 
preventive maintenance guarantee the best trouble-free use of the equipment. This allows you to avoid 
interruptions in use and increases the productivity of the machine.

5.1  Cables

Check the condition of torch, earth and mains cables daily. Do not use damaged cables. Also make  
sure that all extension cables used in the mains connection are in proper condition and compliant  
with regulations.

NOTE!  The mains cables should be repaired and installed only by electrical contractors and 

installers trained and authorised to perform such operations.

5.2  Power source

Before cleaning the interior of the machine, you need to remove the case by unscrewing the mounting 
screws at the top and sides of the machine. 

NOTE!  To prevent damage, wait approximately five minutes after disconnecting the mains cable 

before removing the machine’s case. Perform the following cleaning and maintenance at least 

every six months:

1.

  Clean the interior of the machine and the fan grills net of any dust and grime stains – for 

example, with a soft brush and vacuum cleaner.
• 

Do not use pressurised air. The contaminant may become compressed into the grooves of the 
coolers.

• 

Do not use a pressure-washing device.

2.

  Check the electrical connections of the machine. Clean any oxidised connections, and tighten the 

loosened ones. 
• 

Check for the right tension before you start repairing the connections. 

NOTE!  Remember that the machine may be repaired only by an electrical contractor or installer 

trained and authorised to perform such operations.

5.3  Regular maintenance

Authorised SifWeld service centres can perform regular preventative maintenance by agreement. Tasks 
included in regular maintenance:
• 

Cleaning of equipment.

• 

Inspection and maintenance of the cutting torch.

• 

Checking of connectors, switches, and control knobs.

• 

Checking of electrical connections.

• 

Checking of the mains cable and plug.

• 

Replacement of damaged or worn parts.

• 

Testing and adjustment of the functions and operational values of the machine, if necessary.

• 

Check the function of all switches.

• 

Check that the cooling fan is operating and air is being vented from rear panel.

• 

Check for abnormal vibration, noise or smell during operation.

TXP1P40

Содержание CUT 40 Digital

Страница 1: ...Operation Manual SifWeld CUT 40 Digital www sifweld com Peters House The Orbital Centre Icknield Way Letchworth Garden City Hertfordshire SG6 1ET Tel 44 0 845 130 7757 TSX1P40 Approved PLASMA ...

Страница 2: ...ign EN60974 1 Arc welding equipment Part 1 Welding power sources EN60974 10 Arc welding equipment Part 10 Electromagnetic Compatibility EMC requirements Additional information restrictive use Class A equipment intended for use in locations other than residential By signing this document the undersigned declares as manufacturer or the manufacturer s authorised representative established within the ...

Страница 3: ...amp environments wearing wet clothing and metal structures Try to avoid welding in cramped or restricted positions Ensure that the equipment is well maintained Repair or replace damaged or defective parts immediately Carry out any regular maintenance in accordance with the manufacturer s instructions Safety against fumes and welding gases Locate the equipment in a well ventilated position Keep you...

Страница 4: ...cutting welding area Remove all flammable and combustible materials from the cutting welding zone and surrounding areas Do not cut weld fuel and lubricant containers even if empty These must be carefully cleaned before they can be cut welded Always allow the cut welded material to cool before touching it or placing it in contact with combustible or flammable material Do not work in atmospheres with ...

Страница 5: ... that has reached its end of life must be collected separately and returned to an environmentally compatible recycling facility Handling of compressed gas cylinders and regulators All cylinders and pressure regulators used in welding operations should be handled with care Never allow the electrode electrode holder or any other electrically hot parts to touch a cylinder Keep your head and face away...

Страница 6: ...1 Preface 7 1 1 General 7 1 2 Introduction 8 1 3 Technical Specifications 9 1 4 Overview Of Machines 10 2 Installation 11 3 Operation 12 5 Maintenance 13 6 Warranty 14 Contents 6 TXP1P40 ...

Страница 7: ...uthorised SifWeld dealer or visit the SifWeld website at www sifweld com The specifications presented in this manual are subject to change without prior notice Important notes Items in the manual that require particular attention in order to minimise damage and personal harm are indicated with the NOTE notation Read these sections carefully and follow the instructions Disclaimer While every effort...

Страница 8: ...utting torch ensures exceptionally smooth clean cuts and comes with a quick connect euro adapter to ensure effortless connection and cost effective replacement of the torch The SifWeld Cut40 Digital can be used to efficiently cut mild and low alloy steels stainless aluminium copper titanium and nickel alloys Features 40amp cutting power High 60 Duty cycle 12mm clean cut on steel 15mm severance cut...

Страница 9: ...put KVA 4 8 Open circuit voltage 420 Amperage range A 20 40 Rated Duty cycle 40 C 60 Efficiency 80 Max cutting thickness mm 15 Compressed air pressure required 4 0 bar Dimensions LxWxH mm 435 x 180 x 265 Post flow time S 2 _ Input power supply 1ph Compressed air flow required 140 170 lpm 5 6 CFM TXP1P40 ...

Страница 10: ...ront Rear Panel 1 Alarm LED 2 Power LED 3 Over Temperature LED 4 MCP Knob 5 Cutting Torch Euro Connector 6 Earth Return 7 LCD Display 8 Input Power Switch 9 Air Inlet 10 Power Input Cable Error Messages and fault conditions 1 Overtemperature Wait for the machine to cool and reset 2 Overcurrent Reset the machine by switching OFF then ON 3 Under Pressure 4 Bar Air Pressure not maintained check Air S...

Страница 11: ...ted in heavy rain as the protection class of the machine IP23S allows for limited outside use NOTE Never aim metallic grinding spray sparks towards the equipment Input connection Before connecting the machine you should ensure that the correct supply is available Details of the machine requirements can be found on the data plate of the machine or in the technical parameters shown in the manual The...

Страница 12: ...ularly important when cutting thicker material Make sure that the torch is pointed away from you and the people near you to avoid any danger from sparks and hot metal Push the safety trigger at the side of the torch first then press the switch to start cutting CAUTION Always hold the hand torch away from your body as a precaution against accidental torch firing Be aware of this hazard Failure to d...

Страница 13: ...ast every six months 1 Clean the interior of the machine and the fan grills net of any dust and grime stains for example with a soft brush and vacuum cleaner Do not use pressurised air The contaminant may become compressed into the grooves of the coolers Do not use a pressure washing device 2 Check the electrical connections of the machine Clean any oxidised connections and tighten the loosened on...

Страница 14: ...e of the warranty Any warranty repair must be performed by Weldability Sif or an Authorised SifWeld Service Centre The customer is responsible for all shipping costs and risk associated with items that are returned covered under warranty Weldability Sif may opt to refund the purchase price less any costs and depreciation due to use and wear Faults defects found under warranty should be reported to...

Страница 15: ...on Part number SifWeld Cut40 Digital package TSX1P40 SifWeld Cut40 Digital 4m torch TSX1P4003 Earth return TSX1P4004 Electrode TSX1P4006 Shield cup TSX1P4008 Air diffuser Hi flow air connector TSX1P4005 Tip TSX1P4007 TSX1P4009 TXP1P40 ...

Страница 16: ...16 www sifweld com Peters House The Orbital Centre Icknield Way Letchworth Garden City Hertfordshire SG6 1ET Tel 44 0 845 130 7757 Fax 44 0 800 970 7757 Email sales weldability sif com www sifweld com ...

Отзывы: