10
1.4 Overview of Machine
Front View
Power source front panel layout
1. Alarm LED
2. Power LED
3. Over temperature LED
4. MCP knob
5. Cutting torch euro connector
6. Earth return
7. LCD display
8. Input power switch
9. Air inlet
10. Power input cable
Rear View
8. Input power switch
9. Air inlet
10. Power input cable
www.sifweld.com
Front & Rear Panel
1. Alarm LED
2. Power LED
3. Over Temperature LED
4. MCP Knob
5. Cutting Torch Euro Connector
6. Earth Return
7. LCD Display
8. Input Power Switch
9. Air Inlet
10. Power Input Cable
www.sifweld.com
Front & Rear Panel
1. Alarm LED
2. Power LED
3. Over Temperature LED
4. MCP Knob
5. Cutting Torch Euro Connector
6. Earth Return
7. LCD Display
8. Input Power Switch
9. Air Inlet
10. Power Input Cable
Error Messages and fault conditions
1. Overtemperature, (Wait for the machine to cool and reset)
2. Overcurrent, (Reset the machine by switching OFF then ON)
3. Under Pressure (4 Bar Air Pressure not maintained, check Air Supply)
4. Missing Shieldcup (Check condition and connection of the Shield Cup)
5. Missing Electrode (Check condition and connection of the Electrode)
6. Electrode Short Circuit (Check position and condition of the Electrode)
7. Arc Failure (Check condition of all Torch Connections and Torch Head Parts)
TXP1P40