PVA-3000 Reference Manual
December 2, 2019
Sifos Technologies
Page
85
4.10. Link Status and DUT Receiver Measurements
The PVA-3000 also provides tools for assessing link configuration, link integrity, and port-under-test receiver
performance. These were reviewed earlier in Sections 1.3.12, 2.2.2, 3.9, and 3.11. These measurements might often
be combined with controlled impairments to assess the ability of a port-under-test to tolerate impaired links.
These commands accept the broadcast configuration where
port
= 99,99 when configuring resources, but not when
performing measurements with the
stat
query argument.
Command
Port
Command Parameters
Query
Returned Parameters
pva_link_mon
<
port
>
<
trig off
|
ext
> <
sample link
|
remote
|
local
> <
count
<
samples
>> <
period 20
|
50
|
100
> <
timeout 10
|
100
>
<
clear
>
stat
<reg1>
READY | ARMED |
MEASURING |
TIMEOUT |
+
Link State
LINKED | UNLINKED |
DISCONNECTED
+
Link_Speed
10 | 100 | 1000 | NA
+
Polarity
MDI | MDI-X | NA
+
Link_Duplex
FULL | HALF | NA
+
1000BaseT_Mode
MASTER | SLAVE
| FAULT | NA)
+
samples
&
Link Status
Up’s | Remote OK’s |
Local OK’s
+
Link_Count
+
Pair14
SWAPPED |
NOT_SWAPPED | NA)
<+
Latched Link Status
Latched Rem. Fault
>
Configures and/or performs link configuration (Link Status) or
link integrity analysis (Link Stability). Measurement is
performed on an already established link. Can be used as
an alternative to packet flow to assess link health.
Measurement may be either immediate or event triggered.
Configurations are retained in test port.
trig off
Configures measurement to start immediately upon
stat
query. (
Test Port wake-up default
)
trig ext
Configures measurement to start upon receipt of the
first Event Trigger following a
stat
query.
sample link
Count (instantaneous) link status “UP” samples
over count interval (
Wake-up default
).
sample remote
Count (instantaneous) 1000BaseT Remote
Rx “OK” samples over count interval. Only viable for
1000BaseT links.
sample local
Count 1000BaseT Local Rx “OK” samples.
count
samples
Specifies how many link status samples to
collect. Range is 1 to 100. (
Wake-up default
= 1)
period 20
Sample rate of 20msec (
Test Port Default
).
period 50
Sample rate of 50msec with maximum possible
sampling duration of 5 seconds.
period 100
Sample rate of 100msec with maximum possible
sampling duration of 10 seconds.
timeout 10
Specifies that an Event Triggered measurement
will time out if no trigger occurs within 10 seconds
following
stat
query. (
Wake-up default
)
timeout 100
Specifies that an Event Triggered measurement
will time out if no trigger occurs within 100 seconds
following
stat
query.
clear
Clear latched Link Status & Remote Fault history
stat reg1
Append results with Latched Link Status & Remote
Fault Status (IEEE 802.3 Register 1)
?
Trig._Mode (
OFF | EXT
)
+
#samples
+ Period (
20
|
50
|
100
)
+ Timeout
10
|
100
+ Sample Type
(
Link “up”
|
Remote
“ok”
)
Содержание PhyView PVA-3000
Страница 22: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 22 ...
Страница 70: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 70 ...
Страница 108: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 108 ...
Страница 124: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 124 ...