3.16.7.
Example 7 Measure 1000BaseT Packet Loss in a Switch with Impairments Enabled
Test ports 1,1 and 1,2 need to be connected to a DUT that supports packet forwarding, and supports 1000BaseT
operation with Master timing mode. Test port 1,1 and 1,2 MAC addressing should be pre-configured to send packets to
each other.
Menu
Task
Screen Shot
Port Select
Select the port to transmit packets while
impaired.
Click on
Port 1
in
Slot 1
on the
Slot
Port Select
menu.
Link Config
Configure the test port 1,1 speed and
timing mode.
Select the
Link Config
Tab.
Select
1000BaseT
under
Link Speed
Click
Arm Configuration
Select
Slave
under
Timing Mode
Click
Arm Configuration
Click
RE-LINK
Verify Link to 1000BaseT
Port Select
Select the port to count received
packets.
Click on
Port 2
in
Slot 1
on the
Slot
Port Select
menu.
Link Config
Configure the test port 1,2 speed and
timing mode.
Select
1000BaseT
under
Link Speed
Click
Arm Configuration
Select
Slave
under
Timing Mode
Click
Arm Configuration
Click
RE-LINK
Verify Link to 1000BaseT
Packets
Start the Received Packets Counter
Select the
Packets
Tab
Click
Clear & Start Count
under
Received Packets
Port Select
Select the port to transmit packets while
impaired.
Click on
Port 1
in
Slot 1
on the
Slot
Port Select
menu..
Содержание PhyView PVA-3000
Страница 22: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 22 ...
Страница 70: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 70 ...
Страница 108: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 108 ...
Страница 124: ...PVA 3000 Reference Manual December 2 2019 Sifos Technologies Page 124 ...