background image

3 to 11 

All equipment manufactured by SIERRA CORP. is for use with the type of gas specified on the rating plate and 
for installation will be in accordance with National Fuel Gas Code ANSI Z223.1 (latest edition). 

IMPORTANT: Installing, Operating and Service Personnel:

 

Qualified,  certified  licensed  and/  or  authorized  personnel  who  are  familiar  with  and  experience  in 

state/local installation codes should perform installation of the equipment. Qualified or authorized personnel 
who have read this manual and are familiar with the functions of the equipment should perform operation of 
the equipment. 

Qualified  personnel  who  are  knowledgeable  with  Sierra  equipment  should  perform  service  of  the 

equipment. 

The BTU input rating on all equipment is calibrated for elevations up to 2,000 feet above sea level. All orifice 
drill sizes are referenced for operation at or below this altitude. For operation at elevations above 2,000 feet, 
the BTU rating must be reduced 4% for each 1,000 feet of elevation or the orifice drill size must be changed 
appropriately. For high altitude drill sizes, call your local gas company or Factory Authorized Service Center 

All units are equipped with fixed orifices and cannot be adjusted. If converting the gas appliance from natural to 
propane, or vice versa, all orifices and the regulator must be changed. The correct 
type of gas, for which the unit is configured, is noted on the name plate. The type of gas specified MUST be used. 
For proper conversion, contact a qualified service technician or your Factory Authorized Service Center. 

SHIPPING DAMAGE CLAIM PROCEDURE 

Merchandise must be inspected prior to the carrier leaving your premises. Damage must be noted in writing 
on the BOL and pictures must be taken at this time.  

- For any goods shipped prepaid by MVP Group Corp., and the goods are damaged and/or lost in transit, please

 

call the Logistics Department at MVP immediately (1-888-275-4538)

- MVP Group will not be held responsible for damages that are not notated on the BOL or not reported within

 

5 business days of being delivered.

- For goods shipped via 3rd party carrier, any claim for damages or loss must be made by the consignee

 

directly 

with the carrier. MVP Group Corp. assumes no responsibility for damage or loss while in transit.

INSTALLATION INSTRUCTIONS 

Gas pressure regulator provided with the equipment must be installed when the appliance is connected to gas 
supply. The area around the appliance must be kept free and clear of combustibles such as solvents, cleaning 
liquid,  broom,  rags, etc.  Proper  clearances must  be  provided  at  the  front  of  the  appliance  for  servicing  and 
proper operation. 
Provisions shall be incorporated in the design of the kitchen, to ensure adequate supply of fresh air and adequate 
clearance for air openings into the combustion chamber, for proper combustion, and ventilation. For proper 
operation of the appliance, do not obstruct the flow of combustion and ventilation air. 

Содержание SRPO-24G

Страница 1: ...RPO 24G SRPO 36G READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS EQUIPMENT 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 12000 BISCAYNE BLVD STE 108 MIAMI FL 33181 TEL 786 600 4687 1 844 218 8477 sales mvpgroupcorp com www mvpgroupcorp com ...

Страница 2: ...ation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment MISE EN GARDE Une installation un réglege une modification ine réparation ou un entretien inadécuat peut provoquer des dommager matériels des blessures ou la mort Lisez sougneusement les in...

Страница 3: ...e unit is configured is noted on the name plate The type of gas specified MUST be used For proper conversion contact a qualified service technician or your Factory Authorized Service Center SHIPPING DAMAGE CLAIM PROCEDURE Merchandise must be inspected prior to the carrier leaving your premises Damage must be noted in writing on the BOL and pictures must be taken at this time For any goods shipped ...

Страница 4: ... be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Restraining devices may be attached to the back frame panel of the unit All Sierra appliances are adjusted and tested before leaving the factory effectively matching them to sea level conditions Adjustments and calibrations ...

Страница 5: ...steel wool abrasive clothes cleansers or powders to clean stainless steel surfaces All stainless steel parts should be wiped regularly with hot soapy water during the day and a stainless steel liquid cleaner at the end of the day To remove encrusted materials soak in hot water to loosen the material and then use a wood or nylon scraper Contact the factory factory representative or a local service ...

Страница 6: ...ASSEMBLY Mount Legs on bottom of product the appliance may be further leveled with adjustment in the foot of the leg GAS CONNECTION Note In the SRPO The Legs are an extra accessory are not includes in the equipment ...

Страница 7: ...lation of the equipment should be performed by qualified certified and authorized personnel who are familiar and experienced with local installation codes Before Installation please read instructions completely and carefully Do not remove permanently affixed labels warnings or plates from the product Please observe all local and national codes and ordinances Installation must conform with local co...

Страница 8: ...rall air conditioning system can produce a slight vacuum in the room and or cause air drafts either of which can interfere with the pilot or burner performance and could be difficult to diagnose Air movement should be checked during installation Air openings or baffles may have to be provided in the room if pilot or burner outage problem persists RATING PLATE Information on this plate includes the...

Страница 9: ...FT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVERLOAD OF OIL AND LEFTOVERS CLEAN AND PREPARE PAN NOT HEATING PROPERLY ORIFICES DIRTY CLOGGED CLEAN ORIFICE MAKE SURE THERE IS NO RESTRICTION IN THE ORIFICE BURNER LOW GAS PRESSURE INCREASE GAS PRESSURE TO 5 WC NAT...

Страница 10: ...Sierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any charges exceeding those stated herein must have prior authorization by the factory A special warranty covers the SRF series These units carry the regular one 1 year parts and labor plus an additional...

Страница 11: ...1 514 737 9701 888 275 4538 service mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canada H4P 2P9 786 600 4687 844 218 8477 service mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United States 33181 ...