![Sierra InnovaSonic 203 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/sierra/innovasonic-203/innovasonic-203_instruction-manual_1266438037.webp)
Sierra Instruction Manual
InnovaSonic
®
203 Economical
38
REL AY Ou t p u t Se t u p
0 . No t Re a d y ( NO * R)
Relay Output Setup
Set up the output trigger event sources of the OCT
hardware output components. RELAY is single-tool
for controlling the external device.
The following signal options are available:
0.
Not Ready(NO*R)
1.
Alarm #1
2.
Alarm #2
3.
NET Int Pulse
Date Totalizer
In this menu, it is possible to review the historical
flow data totalizer for any day of the last 64 days, any
month of the last 64 months and any year of the last 5
years.Press
, use the
or
to review
totalizer in days, months and years; “0” for day, “1”
for month, and “2” for year. Use the
or
to
review the totalizer in some day, some month, some
year.
For example, to display the flow total for July 18,
2000, the display “-----------” at the upper right corner
of the screen indicates that it was working properly
the whole day. On the contrary, if “G” is displayed, it
indicates that the instrument gain was adjusted at least
once. Probably it was offline once on that day. If “H”
is displayed, it indicates that poor signal was detected
at least once. Also, it indicates that the operation was
interrupted or problems occurred in the installation.
For info please refer to “Error Code and Resolutions”.
Automatic Flow Correction
With the function of automatic flow correction, the
flow lost in an offline session can be estimated and
automatically adjusted. The estimate is based on the
average value, which is obtained from flow rate before
going offline and flow measured after going online the
next time, multiplied times the time period that the
meter was offline. Select “ON” to use this function
and “OFF” to cancel this function Normally, signal
quality Q value should be better than 50.
Da t e T o t a li z e r
[ 8 2
0 . Da y
0 0 0 3 - 0 4 - 0 5 G- H- I
- 0 m3
0 0 0 3 - 0 4 - 0 5 - - - - - -
>4 3 5 6 .7 8 m3
Au t o ma t i c Co r r e c t i o n
YES