Sierra Instruction Manual
InnovaSonic
®
203 Economical
29
Initial Parameter Setups and Save
Load and save the parameters. 18 different sets of
setup conditions/groups are available to load and save
by three methods (i.e.-you can load and save 18
different applications):
0.
Entry to Save
1.
Entry to Load
2.
To Browse
Select “Entry to Save”, press
. An ID code and
the original parameters are displayed in the menu.
Press
or
to move the ID code, then press
the
key again to save the current parameter in
the current ID room.
When selecting “Entry to Load”, press
, and the
system will read and calculate the parameters
automatically and display the transducer mounting
spacing in Menu M25.
Holding with Poor Sig
Select “Yes” to hold last good flow signal displayed if
the Flow meter experiences a poor signal condition.
This function will allow continued data calculation
without interruption.
Empty Pipe Setup
This parameter is used to overcome the possible
problems that usually show up when the pipe being
measured is empty. Since signals can be transmitted
through the pipe wall, the flow meter may still read a
flow while measuring an empty pipe. To prevent this
from happening, you can specify a value. When the
signal quality falls below this value, the measurement
stops automatically. If the flow meter is already able
to stop measuring when the pipe is empty, a value in
the range of 30 to 40 should also be entered in this
menu to ensure no measurement when the pipe is
empty.
* It should be understood that the instrument is NOT
designed to function correctly on an empty pipe.
Pa r a me t e r Se t u p s
En t r y t o SAVE
Ho ld i n g wi t h Po o r Si g
NO
Emp t y Pi p e Se t u p [ 2 9
0