Sierra Instruction Manual
InnovaSonic
®
203 Economical
14
2.
Pipe Parameter Entry Shortcuts
2.1.
Dual Function Keys Menu Description
Rate/1 Key
Press this key to display Maximum Flow Rate. The
function is the same with Window M02. Press the key
again to see Min. then Avg. Flow rates.
Total/2 Key
Press this key to display Net Totalizer. The function is
the same with Window M00.
Start/Stop/3 Key
Press this key to start and stop Manual Totalizer in
turn.
Cool Cap./4 Key
Reserved for future use.
Heat Cap./5 Key
Reserved for future use..
Temp./6 Key
Reserved for future use.
Flow Vel./7 Key
Press this key to display Velocity. The function is the
same with Window M01.
Sound Vel./8 Key
Press this key to enter Fluid Sound Velocity in
Window M92.
Signal/9 Key
Press this key to display Signal Strength and Signal
Quality. The function is the same with Window M90.
Cal./. Key
Press this key to start Manual Totalizer, then press the
key again to end Manual Totalizer.
Zero/0 Key
Press this key to input code 1234 to set zero.
Flo w Ma x .
3 6 0 .0 0 0 0 m3 / h
Da y T o t a li z e r
7 0 0 .10 0 0 m3
6 0 s e c
ON 10 .12 3 m3
Flo w 0 .112 9 m3 / h * R
Ve l
1.0 4 15 m/ s
Flu i d So u n d Ve lo c i t y
0 .0 0 0 0 m/ s
St r e n g t h + Qu a li t y [ 9 0
UP:0 0 .0 DN:0 0 .0 Q= 0 0
Ma n u a l Ca li b r a t e
Pr e s s En t Wh e n Re a d y
Se t Z e r o
Ple a s e En t e r PW