USE OF SEALANT
Sealant is required on vent system joints, except Metal-Fab Sure-Seal direct vent system joints
(figure 7). On longer vent runs, especially vertical runs, sealant will ensure that the combustion air
enters from outdoors, and not through the vent joints. Use high temperature sealant, available from
local suppliers, on the inner pipe joint, applying the sealant around the outside of the male part of the
vent. A bead of silicone should be used on the outside of the joint after assembly to seal the supply
air. If the venting is disconnected for servicing, be sure to follow above instructions for resealing
venting when reconnecting to system.
FIGURE 7
VENT RESTRICTOR INSTALLATION
VENT RESTRICTOR
To fasten the Restrictor Plate to the ceiling of the firebox:
1/. Remove the 2 screws that are in place
2/. Remove portion of restrictor for your correct air flow
3/. Fasten Restrictor Plate back in place.
NO
T
E
A minimum clearance to combustibles must be maintained around the vent pipe of 1”
on all horizontal and vertical pipe runs
Un dégagement minimum aux matériaux combustibles doit être maintenu autour du
tuyau de 1 "sur toutes les canalisations horizontales et verticales fonctionne
Vent Configuration Restrictor Size
Factory set
60%
Remove 1 side
40%
Remove 2 sides
20%
Apply RTV high temperature
sealant around male pipe.
Содержание Newcomb 36
Страница 18: ...Page 18 of 56 Figure 2...
Страница 51: ...Page 51 of 56 8 0 LABEL INFORMATION...
Страница 53: ...Page 53 of 56 APPENDIX A AMERICAN FLAME VALVE INFORMATION...
Страница 54: ...Page 54 of 56 APPENDIX A Continued...
Страница 56: ...Page 56 of 56 APPENDIX A Continued AF 4000 Wiring Diagram Sierra Flame 1503 7088 18th Ave Burnaby BC V3N 0A2...