Up to 34' (10363 mm) of vertical length
Fire stop
Flashing
Collar
Termination cap part # SV4CGV
Use a ceiling fire stop when penetrating a ceiling or floor. Use a wall thimble when penetrating an inside or
outside wall. Vent terminals shall not be recessed into a wall or siding.
Metal-Fab Venting
The minimum vent system for horizontal termination must consist of:
Metal-Fab adapter Part # 4DDA directly on top of unit
12" (305 mm) length horizontally
Wall thimble part #IMC1082A
Horizontal termination cap
4DHT
The
maximum horizontal
vent system consists of:
Metal-Fab adapter Part # 4DDA 45
°
off the unit
34' (10363 mm) vertical length off the 45
°
pipe
3 - 90 degree elbows
12' (3658 mm) maximum horizontal length
Wall thimble part# IMC1082A
Horizontal termination cap
4DHT
The
maximum vertical
system consists of:
Metal-Fab adapter Part # 4DDA 45
°
off the unit
Up to 34' (10363 mm) of vertical length
Fire stop
Flashing
Collar
Termination cap part # 4DVT
2-Ply Aluminum Flex Vent
The minimum vent system for horizontal termination must consist of:
12” (305 mm) horizontal length (measured from center of vent pipe)
Wall thimble part# IMC1082A
Horizontal termination cap part # IMC1070A or IMC1070B
The
maximum horizontal
vent system consists of:
34’ (10363 mm) vertical length with 3 - 90 degree bends and a 12’ (3658 mm) horizontal length
(measured to center of 45
°
vent pipe)
Wall thimble part# IMC1082A
Horizontal termination cap part # IMC1070A or IMC1070B
Note: Horizontal strapping shall be supported, by means of a steel strap, every 3’.
Venting configuration straight out off 45
°
pipe
Minimum 12” – Maximum 24”
H1
Содержание Newcomb 36
Страница 18: ...Page 18 of 56 Figure 2...
Страница 51: ...Page 51 of 56 8 0 LABEL INFORMATION...
Страница 53: ...Page 53 of 56 APPENDIX A AMERICAN FLAME VALVE INFORMATION...
Страница 54: ...Page 54 of 56 APPENDIX A Continued...
Страница 56: ...Page 56 of 56 APPENDIX A Continued AF 4000 Wiring Diagram Sierra Flame 1503 7088 18th Ave Burnaby BC V3N 0A2...