Cleaning and maintenance
en
37
Drain hose at the siphon is
blocked
1.
Switch off the appliance. Disconnect
the mains plug.
2.
Loosen the hose clamp. Carefully
remove the drain hose; residual
water may leak out.
3.
Clean the drain hose and siphon
connecting piece.
4.
Reattach the drain hose and secure
the connection using the hose
clamp.
Filter in the water supply is
blocked
:
Warning
Risk of electric shock!
The Aqua-Stop contains an electric
valve. There is a risk of electric shock if
you immerse the Aqua-Stop safety valve
in water. Do not immerse the safety
valve in water.
First, reduce the water pressure in the
supply hose:
1.
Turn off the tap.
2.
Select any programme (except
Rinse/Spin/Drain/Empty).
3.
Press the
I
button. Allow the
programme to run for approximately
40 seconds.
4.
Turn the programme selector to the
off position. Disconnect the mains
plug.
5.
Clean the filter on the tap:
Disconnect the hose from the tap.
Clean the filter with a small brush.
6.
For standard and Aqua-Secure
models, clean the filter on the rear of
the appliance:
Remove the hose from the rear of
the appliance.
Use pliers to remove the filter and
then clean it.
7.
Insert the filter, connect the hose and
check for leaks.