08.90
Technical Data
The DB numbers are freely selectable. The number of DB axis and DBWF depends on the
number of WF axes (see planning instructions).
FBs:
FB207
Start functions
FB210
Main program
FB211
Start functions
FB215
Start functions
FB216
for a DUAL-PORT-RAM-Length of 16 Byte
FB217
for a DUAL-PORT-RAM-Length of 32/64 Byte
3.1.3 Note to the ”Basic program” and ”Package 1” of SINUMERIK 3
The user must call the blocks FB70 Menu selection (basic program) and FB77 Input/Output of
data (package 1). Hereby, the FB77 must be called before the FB70, and the D1.3 must be set
back in DB9 shortly before calling FB70 (Therefore, DB9 must be loaded in the RAM area).
3.1.4 Overview of used data blocks
DBWF of basic functions once
for each module
Allocation address list
Format address list
DB designation
Memory type
Length in words
MENU-DB
EPROM
165
19
19
245
37
261
1)
1)
1)
2)
128
64
EPROM
EPROM
RAM
RAM
RAM
RAM
RAM
RAM
RAM
RAM
RAM
Format-DB
Allocation list
Display-DB
WZ-M-A1
WZ-M-A2
WZ-M-A3
DBZU of basic functions
DB-Achse of basic functions
once for each axis
DB-No.
48
49
68
69
79
89
109
129
freely selectable
freely selectable
freely selectable
39
1) 2* number of magazine loc20
2) 2* number of connected axes +11
©
Siemens AG 1990 All Rights Reserved 6ZB5 440-0JB02
3 - 3
WF 725/WF726 (PJ – NC Auxiliary axis and Tool magazine for SINUMERIK 3GA4)