UTMC OTU/MOVA Handbook
667/HB/31601/000
Page 53
Issue 5
6.6.2 MOVA Config Screen
Licence Number (LIN part 1)
This licence number is required to enable MOVA. Enter the first 4 digits of the
value supplied by Poole. The value 9999 in each number can be used to
temporarily enable facilities while a permanent licence number is obtained. The
temporary licence will expire after 7 days.
Licence Number (LIN part 2)
This licence number is required to enable MOVA. Enter the second 4 digits of the
value supplied by Poole. The value 9999 in each number can be used to
temporarily enable facilities while a permanent licence number is obtained. The
temporary licence will expire after 7 days.
Licence Facility Code (LIF)
This licence code is required to enable MOVA. Enter the 6-character string
supplied by Poole.
MOVA Site 1 Name
MOVA Site 2 Name
MOVA Site 3 Name
MOVA Site 4 Name
Alpha-numeric string identifying MOVA stream site 1 (or 2 or 3 or 4).
:
This
must
be the same site name as defined on the OSE Config screen for
the OTU, or MOVA will not have access to any force and confirm bits.
Base IP Port Number
The MOVA IP listening ports are controlled by this value, e.g. for base of 12000,
MOVA 1 uses port 12001, MOVA 2 uses port 12002 etc.. Range 0 to 65535.
:
Change with care as the port number is used by MOVAcomm.