UTMC OTU/MOVA Handbook
667/HB/31601/000
Page 45
Issue 5
6.2.6 SCOOT Detector Mapping via OTU I/O Card
Where an existing Gemini OTU is being upgraded, the SCOOT detector wiring would
normally be retained i.e. detectors connected directly to the OTU rather than the
controller.
2. Modify the SCOOT bit
numbers to match the OTU
detector wiring – numbers start
at 1.
3. SCOOT detectors can be routed
via the OTU I/O using port
“busmova1.in.1”. for I/O card 1etc
1. Select the SCOOT detector
site to edit.
4. Use "Submit" to save the changes to
the screen and then when all changes
completed use “Save to File”.