TEL50.GSM
7.2 Modification of Input-Output identification string
In this section the User can modify the identification string (ALIAS) for the device inputs/outputs. New identification strings will
support the factory’s ones that remain active. Queries or commands can be sent using either factory’s strings or ALIAS set by
the user.
If no changes are made, the factory settings are maintained.
The defined alias will have a maximum length of 10 alphanumeric characters ( 0÷9, A÷Z ). Observe the syntax indicated below.
Note that the characters “space (blank), +, -, _, etc”, are not included and, consequently, are not recognized by the device.
Inputs - Outputs Factory
setting Any
modification Example
Incorrect
example
Alarm input
IN1
max 10 characters ( 0÷9, A÷Z).
ALARM
ALARM 1
Relay output 1
OUT1
max 10 characters ( 0÷9, A÷Z).
BOILER
PUMP+1
Relay output 2
OUT2
max 10 characters ( 0÷9, A÷Z).
LIGHTS
HOME LIGHTS
Temp. sensor input
TEMP
max 10 characters ( 0÷9, A÷Z).
TEMPEXT
TEMPERATURE
Some examples of correct syntax for modifying the identification strings are shown below.
[ALIAS]
SMS command SMS
reply Action
ALIAS IN1=ALARM
IN1=ALARM
identification input 1 with “ALARM”
ALIAS OUT1=BOILER
OUT1= BOILER
identification relay output 1 with “BOILER”
ALIAS OUT2= LIGHTS
OUT2= LIGHTS
identification relay output 2 with “LIGHTS ”
ALIAS ANALOG=TEMPEXT
ANALOG=TEMPEXT (*)
identification analogue input with “TEMPEXT”
(*) factory preset ANALOG=TEMP