Commissioning
7.3 Description of OSD menu
SMD 18101 CS / SMD 18101 CP / SMD 18101 D
7-12
Instruction Manual, 11/2005, A5E00472377A-002
Main menu
Functions
Adjustment/range
Description /
→ Test pattern
Off, colorbars, graybars
Fixed test patterns are
available
The test patterns are
generated directly in the
display's processor. The test
patterns can be used to
analyze whether a fault is
present in the control
electronics or has to be
searched for in the
plugs/cables or video source.
1.
If the test pattern is
displayed without faults,
one should first check the
connections and video
sources.
2.
If the video source and
the connections are OK,
and if the test pattern is
displayed perfectly, the
fault must be searched
for in the video input of
the monitor.
The test patterns can also be
used to check the panel
quality:
•
Proof of the contrast with
gray scales and color
channels (independent of
picture, picture program,
graphics card and
connectors).
•
Complete writing of all
pixels on the display
surface (limitation: the
first column on the left of
the panel remains black).
Test of columns or line
driver.
→ Reset to factory defaults
(only applies with PIP setting
= "Off“)
All parameters are reset
The following are deleted:
•
User settings
•
Custom settings
The following are reset:
•
Backlight
•
Sharpness
•
User color location
•
Signal settings
•
Black level settings
•
RGB relation
•
DPMS settings
•
Language