![Siemens SIWAREX WL200 Series Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/siemens/siwarex-wl200-series/siwarex-wl200-series_operating-instructions-manual_374530024.webp)
Connecting
5.3 Connecting up
SIWAREX WL200
24
Operating Instructions, 07/2016, A5E02199611B-03
Load cells with six-wire system
For connecting cables in the six-wire system, the supply voltage is fed back to the weighing
module as the reference voltage. Shortening or lengthening has no effect on the measuring
result.
Figure 5-2
Connecting principle for load cells with six-wire system
5.3
Connecting up
Signal assignment for the load cell connecting cable
Identifying colors and signal assignment for the connecting cables of load cells not listed:
See the data sheet for the appropriate load cell.