
The Physical Block (PA Slot 0), PROFIBUS
2.3 Physical Block (PA Slot 0) Parameter List, PROFIBUS
SITRANS TH400 PROFIBUS® PA
8
Configuration Manual, 02/2007, A5E01039143-01
2.3
Physical Block (PA Slot 0) Parameter List, PROFIBUS
Parameter
Rel.
Index Description
Type
Store Size R/W Min Max Default
ST_REV
1
Is incremented each time that there is a change in a static
parameter in the physical block.
Unsigned
16
N
2
RO
0
TAG_DESC
2
Tag name of the block. This parameter must be unique in the
configuration.
OCTET_
STRING
SRC
32
R/W
"
STRATEGY
3
This can be used to group a Function Block. It is a user supplied
parameter for identification purpose.
Unsigned
16
SRC
2
R/W
0
ALERT_KEY
4
Current state of alarm blocks
Unsigned 8 SRC
1
R/W
0
TARGET_MODE
5
Current desired mode of the block.
Unsigned 8 SRC
1
R/W
-
MODE_BLK
6
A block has static block parameters, that are not changed by the
process. Values are assigned to this parameter during the
configuration or optimisation. The value of ST_REV must increase
by 1 after every change of a static block parameter. This provides a
check of the parameter revision.
DS-37
D
3
RO
Block
specific
ALARM_SUM
7
Current state of the blocks alarms.
DS-42
D
8
RO
0,0,0,0
SOFTWARE_REVISION 8
Software revision of the device
VISBLE_
STRING
Cst
16
RO
HARDWARE_REVISION 9
Physical revision of the device.
VISBLE_
STRING
Cst
16
RO
DEVICE_MAN_ID
10
Siemens AG manufacturer identification number.
Unsigned
16
Cst
2
RO
0x006D
DEVICE_ID
11
Manufacturer device number
VISBLE_
STRING
Cst
16
RO
SITRAN
S
TH400
DEVICE_SER_NUM
12
Device serial number
VISBLE_
STRING
Cst
16
RO
DIAGNOSIS
13
Bit string indicating the diagnosis of the device. See Diagnosis
OCTET_
STRING
D
4
RO
DIAGNOSIS_
EXTENSION
14
Not used.
OCTET_
STRING
D
6
RO
DIAGNOSIS_MASK
15
Not used.
OCTET_
STRING
Cst
4
RO
DIAGNOSIS_MASK_
EXTENSION
16
Not used.
OCTET_
STRING
Cst
6
RO
DEVICE_
CERTIFICATION
17
PA device certification
VISBLE_
STRING
Cst
32
RO
WRITE_LOCKING
18
If Locked, no writes from anywhere are allowed, except to clear
WRITE_LOCK. Cyclic block inputs will continue to be updated.
Unsigned
16
N
2
R/W
FACTORY_RESET
19
Factory reset:
1:
Restart with default
2506:
Restart processor
2712:
Recover default address to the device
Unsigned
16
SRC
2
R/W
DESCRIPTOR
20
It is a user supplied description of the block in the application.
OCTET_
STRING
SRC
32
R/W
DEVICE_MESSAGE
21
It is a user supplied Message of the block in the application.
OCTET_
STRING
SRC
32
R/W