26
SFIDK.PS.029.Q3.02
Signal conv. inst.
5. Signal converter installation
SITRANS F US SONOFLO
®
®
®
®
®
5.10 Setting the voltage
selector 19" insert
The voltage selector is located on the back of the signal converter. Settings of 115 V a.c. or
230 V a.c. can be chosen.
5.11 Location of
SENSORPROM
®
®
®
®
®
flow memory unit
The SENSORPROM
®
unit is fitted to the cable connection board, see fig.
The SENSORPROM
®
unit is sensor specific and is being packed in the terminal box of the sensor
or by sensor SONO 3100 fixed at the data plate.
To identify the SENSORPROM
®
unit a label indicates the sensor type and serial number. This
number can also be found on the sensor data plate.
In addition, the identity can be read on the SONO 3000 under the menu "SENSOR CHARACTERIS-
TICS". At start up it should always be checked that the identity in the menu matches the identity on
the data plate placed at the sensor.
19" insert in
IP 65 box
19" insert