SITRANS AW
Smart wireless module with power
supply for field devices
WirelessHART Adapter SITRANS
AW200
Operating Instructions
7MP3112-.....-....
02/2020
A5E02777161-AA
Introduction
1
General safety instructions
2
Preparations for use
3
Mode of operation and
system
4
Assembling
5
Connecting
6
Operation (hardware)
7
Commissioning (hardware)
8
Parameter assignment/
addressing
9
Maintenance and service
10
Appendix
A
Страница 1: ...W200 Operating Instructions 7MP3112 02 2020 A5E02777161 AA Introduction 1 General safety instructions 2 Preparations for use 3 Mode of operation and system 4 Assembling 5 Connecting 6 Operation hardware 7 Commissioning hardware 8 Parameter assignment addressing 9 Maintenance and service 10 Appendix A ...
Страница 2: ...se who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used these ...
Страница 3: ...king 13 3 2 Identification of the device 13 3 3 Components of the product 14 3 4 Storage and transport 14 4 Mode of operation and system 17 4 1 Wireless HART network 17 4 2 Siemens HART field devices for the adapter 18 5 Assembling 21 5 1 Overview 21 5 2 Conditions for mounting 22 5 3 Construction 23 5 4 Housing dimensions 24 5 5 Installation on the field device 25 5 6 Mounting at a distance 27 5 ...
Страница 4: ...ing 45 8 4 Connecting a WirelessHART adapter to a computer using a modem 46 8 4 1 Troubleshooting SIMATIC PDM cannot find the WirelessHART adapter 47 9 Parameter assignment addressing 49 9 1 Operating functions using HART communication 49 9 2 Identification 50 9 3 Wireless communication 51 9 4 Wired communication 53 9 5 Illustration of the device variables of the adapter 54 9 6 Configuration of 4 ...
Страница 5: ...A 2 Spare parts and accessories 69 A 3 Technical support 70 A 4 Product documentation 70 Index 73 Table of contents WirelessHART Adapter SITRANS AW200 Operating Instructions 02 2020 A5E02777161 AA 5 ...
Страница 6: ...Table of contents WirelessHART Adapter SITRANS AW200 6 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 7: ...ks AA 02 2020 Section Connecting a WirelessHART adapter to a computer using a modem Page 46 added 1 3 Notes on warranty The contents of this programming manual shall not become part of or modify any prior or existing agreement commitment or legal relationship All obligations on the part of Siemens AG are contained in the respective sales contract which also contains the complete and solely applica...
Страница 8: ...siemens com processinstrumentation catalogs Product information about SITRANS AW200 on the Internet http www siemens de wirelesshart Introduction 1 4 Product information WirelessHART Adapter SITRANS AW200 8 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 9: ...elessHART gateway in the relevant operating instructions 2 3 Qualified Personnel Qualified personnel are people who are familiar with the installation mounting commissioning and operation of the product These people have the following qualifications They are authorized trained or instructed in operating and maintaining devices and systems according to the safety regulations for electrical circuits...
Страница 10: ...battery unit consists of two cells of the type SL 2780 This design has an effect on occupational health and safety Keep to the regulations for avoiding danger in the accompanying safety data sheet Maintenance WARNING Explosion hazard Never open the housing of the WirelessHART adapter within a hazardous area Opening the housing for example during commissioning or replacing the battery is permitted ...
Страница 11: ... the FCC regulations Operation is subject to the two following conditions This device cannot cause dangerous interference The device is not sensitive to interference that can cause unwanted operating states WARNING Keep to the minimum distance between the device antenna and the human body A distance of at least 20 cm must be maintained at all times between the body of the user or other persons in ...
Страница 12: ...ation outside company grounds Norway Operation can be limited to a radius of 20 km around the city of Ny Alesunds Romania Operation as a secondary device Special license required Latvia Operation in the open of the 2 4 GHz frequency range requires a national authori zation General safety instructions 2 6 Conformity certificate WirelessHART Adapter SITRANS AW200 12 Operating Instructions 02 2020 A5...
Страница 13: ...f you find that the content is damaged the device must not be put into operation In this case contact your sales partner Return the device to us where possible in its original packaging 3 2 Identification of the device Type plate The type plate contains all the information you require to identify your device Product name Electrical data Field of application Wireless approvals FCC IC Frequency rang...
Страница 14: ...ve to strong vibration and shock This means that the WirelessHART adapter needs to be protected against excessive mechanical stress of this type Storage We recommend that you store the device without the battery unit connected at temperatures from 40 C to 80 C If you store the device with the battery unit connected the storage temperature must not exceed 30 C NOTICE Avoid direct sunlight and the i...
Страница 15: ...and substances If you transport the battery the dangerous goods regulations listed in the accompanying safety data sheet apply For more information please contact your regional Siemens representative Partner http www automation siemens com partner Preparations for use 3 4 Storage and transport WirelessHART Adapter SITRANS AW200 Operating Instructions 02 2020 A5E02777161 AA 15 ...
Страница 16: ...Preparations for use 3 4 Storage and transport WirelessHART Adapter SITRANS AW200 16 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 17: ...d makes it available in the plant network IE WSN PA LINK SIMATIC system SITRANS AW200 SIMATIC ET 200 with HART support SITRANS TF280 SITRANS P280 DP PA LINK Industrial Ethernet PROFIBUS WirelessHART PROFIBUS PA ES OS MS Figure 4 1 Wireless HART network Due to technical conditions it is often impossible to transfer diagnostics data from HART field devices to a higher level process control system Th...
Страница 18: ...he wireless network This means that the user is not required to make any settings regarding the organization of the network Power supply of the WirelessHART adapter The power required by the WirelessHART adapter is provided by the supplied battery unit The field device can be supplied by the battery unit or by a separate power supply It is possible to connect two wire and four wire field devices I...
Страница 19: ...the power supply You will find further information on this in the section Optimization of the power supply supply by the adapter Page 61 Mode of operation and system 4 2 Siemens HART field devices for the adapter WirelessHART Adapter SITRANS AW200 Operating Instructions 02 2020 A5E02777161 AA 19 ...
Страница 20: ...Mode of operation and system 4 2 Siemens HART field devices for the adapter WirelessHART Adapter SITRANS AW200 20 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 21: ... and field device connectors various interchangeable couplings can be screwed into the mounting collar of the WirelessHART adapter Mounting accessories Depending on what was ordered the following mounting accessories are supplied with the WirelessHART adapter 1 Coupling for mounting on a field device with M20 G 1 2 NPT 1 2 or NPT 3 4 connector Mounting support for mounting on a wall or a pipe Wire...
Страница 22: ...ll the adapter at a distance from the field device make sure that the antenna is at least 6 cm away from a wall or mast Make sure that the antenna of the WirelessHART adapter is not located between a wall or a mast and the housing Make sure that there is no metallic material parallel to the antenna with a clearance of less than 6 cm Make sure that the antenna is aligned vertically and pointing upw...
Страница 23: ...screwdriver with a blade width of 2 5 mm 5 3 Construction Antenna Locking nut Mounting collar Cable inlet for installation on the field device inner thread M20x1 5 Secondary cable inlet inner thread M20x1 5 Cover of the adapter with battery compartment Figure 5 2 Side view of the housing Assembling 5 3 Construction WirelessHART Adapter SITRANS AW200 Operating Instructions 02 2020 A5E02777161 AA 23...
Страница 24: ...5 4 Housing dimensions Figure 5 3 Housing dimensions in mm inches Assembling 5 4 Housing dimensions WirelessHART Adapter SITRANS AW200 24 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 25: ...king nut is loosened the connecting collar can be rotated without needing to turn the housing of the WirelessHART adapter Assembling 5 5 Installation on the field device WirelessHART Adapter SITRANS AW200 Operating Instructions 02 2020 A5E02777161 AA 25 ...
Страница 26: ...se steps 1 Remove the sealing cap on the mounting collar 2 Push one EPDM seal onto each end of the double thread coupling up to the end of the thread Assembling 5 5 Installation on the field device WirelessHART Adapter SITRANS AW200 26 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 27: ...n a variety of situations This might be for example There is not enough space to install the adapter on the field device The reception of the wireless signals is not adequate where the field device is located The vibration on the field device is higher than the recommended range The WirelessHART adapter can be secured to a wall a mast or other objects In this case the connection between the Wirele...
Страница 28: ...ckwise 2 Insert the mounting collar of the WirelessHART adapter through the hole in the bracket 3 Align the WirelessHART adapter so that you can position the antenna vertically when mounting is complete 4 Fit the locking nut on the mounting collar and tighten the locking nut clockwise Assembling 5 7 Wall and pipe mounting WirelessHART Adapter SITRANS AW200 28 Operating Instructions 02 2020 A5E0277...
Страница 29: ...hecks Is the WirelessHART adapter damaged visual check Does the WirelessHART adapter satisfy the specifications for the location such as ambient temperature relative humidity etc Is the antenna correctly aligned Is the WirelessHART adapter installed far enough away from a wall a pipe or a mast Is the mounting support for the wall pipe correctly mounted Have the mounting collar and locking nut been...
Страница 30: ...Assembling 5 8 Checks after mounting WirelessHART Adapter SITRANS AW200 30 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 31: ... electromagnetic interference can be expected for example from machines or wireless devices we recommend that you use a shielded cable Contact the shield only to the ground connector Cabling when the adapter is mounted directly on the field device If the adapter is installed directly on the field device follow these steps 1 Open the housing of the WirelessHART adapter 2 Insert the cable through th...
Страница 32: ...t Cabling with the optional cable inlet To feed a cable into the housing through the optional cable inlet follow these steps 1 Remove the sealing cap from the cable inlet of the WirelessHART adapter 2 Screw the cable gland into the thread of the cable inlet 3 Release the stress relief of the cable gland slightly by turning the union nut counterclockwise 4 Open the housing of the WirelessHART adapt...
Страница 33: ...ric current 4 mA DC Iin 20 mA DC according to NAMUR recommendation NE 43 High resistance HART input output connectors terminals 4 5 6 Input impedance 3 7 kΩ for HART communication Input impedance DC Checking the terminal connections After wiring up the WirelessHART adapter make the following checks Are the terminals wired up correctly Is the cable gland tight 6 2 Wiring diagrams 6 2 1 Overview Opt...
Страница 34: ... measurement in the range from 4 to 20 mA Digital HART communication Connect up the WirelessHART adapter as illustrated LUHOHVV 57 DGDSWHU ZLWK WHUPLQDOV WR LHOG GHYLFH Figure 6 2 Connection of a two wire field device and supplying the device with power 6 2 3 Four wire field device When you connect a four wire field device the following functions are possible via terminals 2 and 3 Current measurem...
Страница 35: ...ommunication If there is a communication resistor then the following connection guidelines will apply WirelessHART communication parallel to a wired HART installation Page 37 Standard connection variant With this connection variant of the WirelessHART adapter the following functions are possible Current measurement in the range from 4 to 20 mA Digital HART communication Connect up the WirelessHART...
Страница 36: ...VLVWRU LUHOHVV 57 DGDSWHU ZLWK FRQQHFWLRQ WHUPLQDOV WR LHOG GHYLFH Figure 6 5 Connection of a two wire field device with external power supply without communication resistor alternative 2 Multidrop connection With this connection variant up to four two wire field devices with external power supply can be connected to the adapter Connect up the WirelessHART adapter as illustrated Connecting 6 2 Wir...
Страница 37: ... to an existing installation consisting of power supply including communication resistor and HART field device Digital communication is possible Connect up the WirelessHART adapter as illustrated ORVHG DQG RSHQ ORRS FRQWURO ZLWK FRPPXQLFDWLRQ UHVLVWRU LHOG GHYLFH LUHOHVV 57 DGDSWHU ZLWK WHUPLQDOV WR Figure 6 7 WirelessHART connection parallel to wired HART communication Connecting 6 2 Wiring diagr...
Страница 38: ...llowing connection variant is recommended 1 2 3 4 5 6 ORVHG DQG RSHQ ORRS FRQWURO ZLWK FRPPXQLFDWLRQ UHVLVWRU LHOG GHYLFH LUHOHVV 57 DGDSWHU ZLWK WHUPLQDOV WR Figure 6 8 Parallel WirelessHART connection when installing a new field device Connecting 6 2 Wiring diagrams WirelessHART Adapter SITRANS AW200 38 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 39: ... health and safety Page 10 The following display and control elements are visible inside the WirelessHART adapter LEDs Red Active communication error message Yellow Communication status Green Battery status Pushbutton Socket for battery connector Figure 7 1 Display and control elements on the board cover WirelessHART Adapter SITRANS AW200 Operating Instructions 02 2020 A5E02777161 AA 39 ...
Страница 40: ...Measurement was stopped on the field device A connection is not guaranteed The WirelessHART adapter can still be operated Supply of the field device is no longer possible Off Empty The battery unit is empty or not connected Red LED Active communication error message Red LED Communication status Meaning Lit Internal error Problem with device specific cause The problem cannot be corrected by the use...
Страница 41: ... red LED flashes Frequency 1 25 Hz 1 25 times s on and 1 25 times off The firmware and the configuration are reset to the default settings of the vendor During operation Time pressed Function 0 2 s No function 0 2 5 s LED function test 5 to 10 s Activates connection establishment Yellow LED flashes at 3 Hz 3 times s on and 3 times off 10 to 15 s Activates the mode for configuration of the connecte...
Страница 42: ...Operation hardware 7 3 Pushbutton WirelessHART Adapter SITRANS AW200 42 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 43: ... approved by the manufacturer Before you install or remove a battery unit make sure that it is not damaged Note The performance of the battery is impaired if the ambient temperature is too high or too low A low ambient temperature causes a voltage drop in the battery unit possibly to a point that the device can no longer be operated A high ambient temperature causes limitation of the power of the ...
Страница 44: ... insert it in the battery compartment Make sure that the battery unit locks audibly in the battery compartment 2 Plug the battery connector into the socket on the board cover Once the WirelessHART adapter is supplied with current the operating software starts up A self test is then performed on the WirelessHART adapter to check whether the attachments to the terminals have been changed If the devi...
Страница 45: ...d the section Operator control hardware Page 39 to see which functions you can perform during operation of the WirelessHART adapter by pressing the pushbutton 8 3 Checks after commissioning Checking the commissioning of the WirelessHART adapter During commissioning of the WirelessHART adapter make the following checks Is the battery unit correctly inserted and the battery connecting cable correctl...
Страница 46: ...ation resistor connect a resistor parallel to the HART modem and connect it to eyes 7 and 8 57 PRGHP b If the WirelessHART adapter is operated with a field device in a control loop with communication resistor the communication resistor of the HART modem becomes obsolete 2 Start the computer and then plug the connection plug of the HART modem into the port If you are using a USB port the computer w...
Страница 47: ...igned to the HART modem 8 4 1 Troubleshooting SIMATIC PDM cannot find the WirelessHART adapter Possible cause Solution Incorrect address range selected in the parameterization tool By default the address of the WirelessHART adapter is 15 Select the address range so that the address of the Wireles sHART adapter is in this range See section Identification Page 50 A different USB or COM port was used...
Страница 48: ...Commissioning hardware 8 4 Connecting a WirelessHART adapter to a computer using a modem WirelessHART Adapter SITRANS AW200 48 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 49: ...nect a PC to the WirelessHART adapter or a connecting cable to connect a HART communicator to the WirelessHART adapter Note Using SIMATIC PDM The following software requirements apply when you use SIMATIC PDM as configuration tool Use EDD device description as of SIMATIC PDM V6 0 only with Service Pack 5 and Hotfix 2 SIMATIC PDM V6 0 SP5 HF2 Make sure that the latest device version has been import...
Страница 50: ...proceed as follows to prevent this behavior 1 Configure the adapter basically for wireless communication for example with the quick start wizard in SIMATIC PDM 2 Make additional configuration settings wireless using a WirelessHART Gateway 9 2 Identification Here you can configure the parameters required to identify the WirelessHART adapter The default settings are shown in the relevant input boxes...
Страница 51: ... Serial number of the WirelessHART adapter Order number Order number of the WirelessHART adapter Order number exten sion Extension to the order number Country Code for the country in which the Wireles sHART adapter is operated DE DE SI units All the unit related parameters of the Wireles sHART adapter can be selected SI units only All SI units only All 9 3 Wireless communication Here you configure...
Страница 52: ...at hexa decimal part 1 of 4 Join key part 2 of 4 Network password 8 characters format hexa decimal part 2 of 4 Join key part 3 of 4 Network password 8 characters format hexa decimal part 3 of 4 Join key part 4 of 4 Network password 8 characters format hexa decimal part 4 of 4 Network search time s Time for active join attempts in s after entering the correct join key and the correct network ID Fol...
Страница 53: ...s in the neighborhood to which a connection is established Number of requests Specifies the number of packages requesting entry to the network sent by neighboring devi ces or network managers and received by the WirelessHART adapter Join attempts Specifies the number of attempts made by the WirelessHART adapter to join the network be fore it succeeded Network search time s Time in seconds during w...
Страница 54: ...ddress Address at which the WirelessHART adapter be gins to search for connected field devices 0 0 Highest scan address Address up to which the WirelessHART adapter scans for connected field devices 1 1 9 5 Illustration of the device variables of the adapter The WirelessHART adapter can output the value and status of various variables Four variables can be represented in the network They can be re...
Страница 55: ...teristic curve are disabled Off the linearization table is disabled the X and X values of the characteristic curve are enabled Linear Linear End value Upper range end value of the input current that corresponds to the 20 mA value 100 C 20 mA Start value Lower range end value of the input current that corresponds to the 4 mA value 20 C 4 mA Damping Damping factor of the input current 0 255 s Curren...
Страница 56: ...led Enabled in WirelessHART Wireless Subdevice index Based on the relevant long TAG the subdevice index lists the connected HART field devices and the adapter so that they can be selected for the burst mode configuration In HART field devices with a HART version 5 or lower the Message parameter is shown in the subdevice index in stead of the long TAG Tank 5 Update period s If the message trigger m...
Страница 57: ...mand number Select the field device variable to be transferred from the list this is only possible for the WirelessHART adapter If you want to set the burst for a connected field device check the operating instructions of the field device for the assignment of device variables 9 8 Configuring event monitoring Configuring event monitoring Event notification is a special application within the burst...
Страница 58: ... must persist before the event notification is sent 3600 Event status Indicates whether and which event notification was sent and has not yet been acknowledged Time first unack event trig gered Indicates how long the event notification shown in event status has existed in seconds 1 Event mask Parameter Meaning Example Event mask To enable the required event notification select the relevant check b...
Страница 59: ...ion with any connected field device The WirelessHART adapter is used for example as a router between other WirelessHART devices Auto If the connected field device is control led via wireless it is supplied with power fol lowing each communication according to the Power on time after external trigger This suppresses constant turning on and off Configuration If configuration is selected the connecte...
Страница 60: ...iguration must be selected 300 s 300 s Last battery change Shows the date on which the Battery change button was last pressed If the WirelessHART adapter is not connec ted to the network during the initial commis sioning the date is set to 01 01 1970 The first time is is connected to the network manager the date is updated Temperature min Lowest temperature in degrees Celsius that the WirelessHART...
Страница 61: ...t you operate the field device in multidrop mode This mode keeps the power output more or less constant at 4 mA so that less energy will be consumed than with active power output Note Reduced battery life The power supply of a field device with the adapter reduces the life of the adapter battery Depending on the set parameters and the environmental conditions battery life may be less than one year...
Страница 62: ...dapter Page 18 Two wire field device with external power supply Page 35 Parameter assignment addressing 9 10 Optimization of the power supply supply by the adapter WirelessHART Adapter SITRANS AW200 62 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 63: ...ce or in the environment Only use the battery type approved by the manufacturer Before you install or remove a battery unit make sure that it is not damaged Note Qualified Personnel Installation and removal of the battery unit must only be carried out by qualified personnel Additional information is available under Qualified Personnel Page 9 Replacing the battery unit To replace the battery unit f...
Страница 64: ... the power supply Page 58 10 2 Return process for battery operated devices WARNING Remove the battery unit before returning the device Before returning the device remove the battery unit Battery units must not be returned Lithium thionyl chloride high performance batteries belong to dangerous goods class 9 Miscellaneous hazardous materials and substances Read the accompanying safety data sheet Ret...
Страница 65: ...rt before returning it in order to ensure that all hollow areas are free of hazardous substances Check the item after it has been cleaned Any devices replacement parts which are returned without a decontamination declaration will be cleaned at your cost before further processing The form is available on the Internet 10 3 Disposal Note Environmental protection The high performance battery used cont...
Страница 66: ...Maintenance and service 10 3 Disposal WirelessHART Adapter SITRANS AW200 66 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 67: ...ation interfaces Input for 4 20 mA and or HART field devices Input output for HART communication Auxiliary power Battery Input and output connection values of the terminals Power supply for field devices terminal 1 No load voltage can be set between 8 V and 23 V in steps less than 0 1 V Electric current 4 mA DC Iout 20 mA 4 20 mA HART input terminal 2 4 mA DC Iin 20 mA High resistance HART input o...
Страница 68: ...nity of heating appliances protect from direct sunlight Temperature limitations See Temperature limitations Page 68 Impact resistance Complying with IEC68 2 27 15 g 11 ms 1 shock in plus and minus direction in each of the 3 orthogonal main axes of the test specimen Vibration resistance Complying with IEC68 2 64 20 f 2000 Hz 0 01 g Hz A 1 2 Temperature limitations Minimum operating temperatures The...
Страница 69: ...40 C 40 C 40 C 35 C 35 C 14 V 40 C 40 C 40 C 40 C 40 C 40 C 35 C 35 C 35 C 35 C 16 V 40 C 40 C 40 C 40 C 40 C 35 C 35 C 35 C 30 C 30 C 18 V 40 C 40 C 40 C 40 C 40 C 35 C 35 C 30 C 30 C 25 C 20 V 40 C 40 C 40 C 35 C 35 C 35 C 30 C 30 C 25 C 25 C 22 V 40 C 40 C 40 C 35 C 35 C 35 C 30 C 30 C 25 C 25 C 1 Information of start up current is available in the following sections Configuring power supply Pa...
Страница 70: ...bout the device contact your local Siemens representative at Personal Contact http www automation siemens com partner To find the contact for your product go to all products and branches and select Products Services Industrial automation Process instrumentation Contact address for business unit Siemens AG Digital Industries Process Automation Östliche Rheinbrückenstr 50 76187 Karlsruhe Germany A 4...
Страница 71: ...mber Using the PIA Life Cycle Portal you can access the serial number specific product information including technical specifications spare parts calibration data or factory certificates Entering a serial number 1 Open the PIA Life Cycle Portal ttps www pia portal automation siemens com 2 Select the desired language 3 Enter the serial number of your device The product documentation relevant for yo...
Страница 72: ...Appendix A 4 Product documentation WirelessHART Adapter SITRANS AW200 72 Operating Instructions 02 2020 A5E02777161 AA ...
Страница 73: ...tion mode 40 Communication resistor 33 34 38 Communication status 40 Components of the product 31 Conditions for mounting 22 Configuration 41 45 Configuration of 4 to 20 mA communication Configuring parameters 55 Configuring burst mode Configuring parameters 56 Configuring event monitoring Configuring parameters 57 Configuring parameters 50 Configuring power supply Configuring parameters 58 Connec...
Страница 74: ...Multidrop mode 43 N NAMUR 33 National guidelines 12 Network 40 Network password 52 No load voltage 33 67 Non hazardous area version 11 O Operating software 44 Operation 13 Operator input 11 Optimum parameter settings 61 Order number 51 P Packaging 13 Parameter Burst command number 57 Burst message trigger mode 56 Burst mode 56 Burst trigger class 56 Burst trigger level 57 Burst trigger unit 56 Bur...
Страница 75: ...5 Unit of the primary variable 54 Unit of the quaternary variable 55 Unit of the secondary variable 54 Unit of the tertiary variable 55 Units 51 Update period s 56 Upper fault current value 55 Upper limit of proportional range 55 Wireless mode 52 X1 X32 56 Y1 Y32 56 Parameter assignment recommendation Wireless communication 50 Parameter assignment software SIMATIC PDM 49 Pipe 29 Power consumption ...
Страница 76: ...cy band 67 Two wire field device 18 33 U Union nut 32 Unpacking 54 V Vibration 14 27 Vibration resistance 68 Visual inspection 13 Viton seal 26 W Wall 22 27 29 Weight 68 Wired communication Configuring parameters 53 Wireless communication Configuring parameters 51 Wireless module 17 Wireless signal 17 27 52 Wiring 31 33 Wrench 23 Index WirelessHART Adapter SITRANS AW200 76 Operating Instructions 0...