Automatic mode
6.9 Execute from external
Surface grinding
Programming and Operating Manual, 11/2012, 6FC5398-5CP10-3BA0
83
At the end of the program or in case of <RESET>, the program is automatically removed
from the control system.
Note
For "Execute externally", no block search is possible.
Requirements for external execution via network
●
The control system and the external PC are connected via Ethernet.
●
The RCS tool is installed on the PC.
The following conditions are required on the the devices:
1.
Control: (see "User Management")
–
Create an authorization for using the network using the following dialog:
Operating area <SYSTEM> > "Service Display" > "Service Control" > "Service
Network" > "Authorization" > "Create"
2.
Control: (see "User log in - RCS log in")
–
Log in for the RCS connection using the following dialog:
Operating area <SYSTEM> > vertical softkey "RCS log in" > "Log in"
3.
PC:
–
Start the RCS tool.
4.
PC:
–
Activate the drive/directory for network operation.
5.
PC:
–
Establish an Ethernet connection to the control.
6.
Control: (see "Connecting / disconnecting a network drive")
–
Connect to the directory released for sharing on the PC using the following dialog:
Operating area <SYSTEM> > "Service Display" > "Service Control" > "Service
Network" > > "Connect" > "RCS Network" (select a free drive of the control > Enter the
server name and the directory released for sharing on the PC, for example:
"\\123.456.789.0\External Program")