Configuring with Web Based Management
4.7 Remote connections
SINEMA Remote Connect - Server
68
Operating Instructions, 11/2017, C79000-G8976-C383-04
4.7.1.2
Create new device
Procedure
1.
Click the "Create" button on the page of the device list.
2.
Configure device setting
–
Specify the following for the device.
Box
Meaning
Name of the device
Enter a name.
The name must meet the following conditions:
•
It must be unique
•
it must start with a letter.
•
The following characters are permitted: a-z, A-Z,0-9 and _
•
"conn" cannot be used as a name.
Type of connection
1.
Permanent: The VPN connection exists permanently:
2.
Digital input: The VPN connection is established as soon as a
signal is applied to the "digital input".
3.
Wake-up SMS: An alarm SMS message is sent to the device.
4.
Digital input & Wake-up SMS
SMS gateway provider
Can only be selected with the type of connection "Wake-up SMS"
or "Digital input & Wake-up SMS".
Select the SMS gateway provider. You configure the gateway pro-
vider in "System > SMS & e-mail"
GSM number
For SCALANCE M-800 with SIM card:
Call number of the end device to which the wake-up SMS is sent.
–
If required, enter additional device information and click the "Continue" button..