![Siemens SINEMA Remote Connect Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/siemens/sinema-remote-connect/sinema-remote-connect_operating-instructions-manual_1266034040.webp)
Configuring with Web Based Management
4.2 Starting the WBM
SINEMA Remote Connect - Server
40
Operating Instructions, 11/2017, C79000-G8976-C383-04
Result
During the logon, a check is made to establish whether the PKI certificate is valid. Then a
check is made as to whether the attributes of the PKI DN filter rules are included in the PKI
certificate.
●
User identification
If the PKI DN filter rule applies precisely to a user, this user is logged on with the SINEMA
RC Server with the user name, see section "Creating new users".
●
Temporary users
If the PKI filter rule applies to a role, a temporary user "pkiuser_X" is created. The
temporary user is listed in "User accounts > Users & Roles". The user receives the right
and the access to the participant groups assigned to the role.
In the role you also specify when the temporary user will be deleted, see section
"Managing role and rights". You can also delete the temporary user in "User accounts >
Users & Roles".
Locking out Smartcard / user certificate
To lock out users, you have the following options:
●
Revocation list
●
PKI DN blacklist
●
Expired user certificate
●
Automatic blocking of the Smartcard after entering the wrong PIN several times. Only the
issuer of the Smartcard can release this again.
You will find more information on the certificate revocation list and PKI DN blacklist in the
section "Locking out Smartcard / user certificate".
PKI DN filter rules
The attributes of the names (Distinguished Name acc. to the X.509 standard) are used as
filter criteria for the filter rules.