State Freigabe
Autor Pauluhn
Access
#
#
#
#
SSH
When SSH remote access is switched on, the SINAUT MD740-1
can be configured from a remote computer. To do so, a connection
must first be established from the remote site to the
SINAUT MD740-1 using an SSH-capable program. To perform
settings in the SINAUT MD740-1 enter the command "gaiconfig"
via the SSH console.
This option is switched off as default.
!
N.B.:
When you enable remote access, make sure that a secure root
and administrator password have been determined.
!
N.B.:
With SSH access via the root password it is possible to
misconfigure the device in such a way that it has to be sent in
for servicing. In this case, please contact your dealer or
distributor.
To enable SSH remote access, make the following settings:
Enable SSH remote access: Yes / No
If you want to enable SSH remote access, set this switch to
Yes
.
!
In this case, make sure that the firewall rules on this page
are set so that the SINAUT MD740-1 can be accessed from
the outside.
Port for incoming SSH connections (remote administration
only)
Default:
22
You can determine a different port.
!
If you have determined a different port, the remote site
which makes the remote access must then give the port
number that is set here before the IP address in the address
information.
Example: