Know-how protection with and without copy protection
To protect your drive unit settings against unauthorized copying, in addition to know-how
protection, you can also activate copy protection.
.QRZKRZSURWHFWLRQ
.QRZKRZSURWHFWLRQZLWK
EDVLFFRS\SURWHFWLRQ
.QRZKRZSURWHFWLRQZLWK
H[WHQGHGFRS\SURWHFWLRQ
.QRZKRZSURWHFWLRQ
ZLWKRXWFRS\SURWHF
WLRQ
Figure 5-2
Setting options for know-how protection
Know-how protection with copy protection is only possible with a Siemens memory card.
Know-how protection without copy protection
The drive unit is only operable with a memory card. You can transfer drive unit settings to other
drive units using a memory card, an operator panel, or STARTER.
Know-how protection with basic copy protection
The drive unit can only be operated if the associated memory card with the drive unit settings
is inserted into it. After replacing a drive unit, to be able to operate the new one with the settings
of the replaced drive unit without knowing the password, the memory card must be inserted
in the new drive unit.
Know-how protection with extended copy protection
The drive unit can only be operated if the associated memory card with the drive unit settings
is inserted into it. It is not possible to insert and use the memory card in another drive unit
without knowing the password.
5.2.2.2
Features of know-how protection
Features when know-how protection is active
The active know-how protection provides the following:
● With just a few exceptions, the values of all adjustable parameters p … are invisible. In
STARTER, instead of the parameter values, the text "know-how protected" is displayed.
You can hide know-how protected parameters in the expert list of STARTER using the
"Without know-how protection" display filter.
● The values of monitoring parameters r … remain visible.
● STARTER does not display any screen forms.
● Adjustable parameters cannot be changed using commissioning tools.
When know-how protection is active, support can only be provided (from Technical Support)
after prior agreement from the machine manufacturer (OEM).
Security measures for SINAMICS
5.2 Write protection and know-how protection
Industrial Security
Configuration Manual, 08/2017, A5E36912609A
35
Содержание SINAMICS
Страница 6: ...Table of contents Industrial Security 6 Configuration Manual 08 2017 A5E36912609A ...
Страница 8: ...Introduction Industrial Security 8 Configuration Manual 08 2017 A5E36912609A ...
Страница 18: ...Industrial Security 3 4 Security management Industrial Security 18 Configuration Manual 08 2017 A5E36912609A ...
Страница 222: ...Communication A 1 Communication Industrial Security 222 Configuration Manual 08 2017 A5E36912609A ...
Страница 224: ...Service Support Industrial Security 224 Configuration Manual 08 2017 A5E36912609A ...