Intelligent Operating Panel 2 (IOP-2)
Operating Instructions, 06/2020, FW V2.6, A5E39549448B AH
27
Setup Menu
6
Overview
The IOP-2 Setups are question-driven environment that assist the user to set-up various
functions and applications of the converter.
WARNING
Motor Identification (Motor ID) function will run automatically
Using the "Standard Drive Control" or "Dynamic Drive Control" in Quick Startup, the Motor ID
function, if selected, is activated at the end of the commissioning squenence.
The motor identification (motor ID) function, after the completion of the Quick Startup,
upon the first startup, will start automatically after approx. 8 to 30 s and accelerate the
motor to the setpoint speed.
This action must be taken into account when the Quick Startup procedure has been
completed, to ensure that the first ON/RUN command when given for your application, does
not produce an unpredicted or unsafe effect on personnel, equipment or premises.
WARNING
Safe and stable state of the converter
During the setup of the converter it is essential to ensure that the system is in a safe and
stable state, as some setup processes have the potential to start the motor. Therefore it is
important to secure any loads and ensure that should the motor start, no potentially
dangerous conditions exist.
CAUTION
Default datasets
The Setups use the default Drive datasets (DDS0 and CDS0), if the default datasets are
changed to the other datasets, the Setups may not function correctly.