4.6.7
Other ways to back up settings
You can backup three additional settings of the parameters in memory areas of the inverter
reserved for this purpose. You will find additional information in the List Manual under the
following parameters:
Parameter Description
p0970
Resetting drive parameters
Load the back-up setting (number 10, 11 or 12). You overwrite your actual parameter
setting when loading.
p0971
Saving parameters
Backing up the setting (10, 11 or 12).
You can back-up up to 99 additional parameter settings on the memory card. You will find
additional information in the List Manual under the following parameters:
Parameter Description
p0802
Data transfer with memory card as source/target
p0803
Data transfer with device memory as source/target
p0804
Start data transfer